Filtered by vendor Tendacn Subscriptions
Total 157 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2024-33181 2 Tenda, Tendacn 3 Ac18, Ac18 Firmware, Ac18 Firmware 2025-04-07 8.8 High
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceMac parameter at ip/goform/addWifiMacFilter.
CVE-2025-29032 1 Tendacn 2 Ac9, Ac9 Firmware 2025-04-03 5.9 Medium
Tenda AC9 v15.03.05.19(6318) was discovered to contain a buffer overflow via the formWifiWpsOOB function.
CVE-2025-29357 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the startIp and endIp parameters at /goform/SetPptpServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29359 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the deviceId parameter at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29358 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the firewallEn parameter at /goform/SetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29361 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the list parameter at /goform/SetVirtualServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29360 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the time and timeZone parameters at /goform/SetSysTimeCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29362 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the list parameter at /goform/setPptpUserList. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29363 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to buffer overflow via the schedStartTime and schedEndTime parameters at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2024-50854 2 Tenda, Tendacn 3 G3, G3, G3 Firmware 2025-03-14 8.8 High
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a stack overflow via the formSetPortMapping function.
CVE-2024-8224 2 Tenda, Tendacn 3 G3 Firmware, G3, G3 Firmware 2024-12-13 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2764 2 Tenda, Tendacn 3 Ac10u, Ac10u Firmware, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-50853 2 Tenda, Tendacn 3 G3, G3, G3 Firmware 2024-11-21 8.8 High
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetDebugCfg function.
CVE-2024-50852 2 Tenda, Tendacn 3 G3, G3, G3 Firmware 2024-11-21 8.8 High
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetUSBPartitionUmount function.
CVE-2024-6403 1 Tendacn 2 A301, A301 Firmware 2024-11-21 6.5 Medium
A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-6402 1 Tendacn 2 A301, A301 Firmware 2024-11-21 6.5 Medium
A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-6189 1 Tendacn 2 A301, A301 Firmware 2024-11-21 8.8 High
A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-41473 2 Tenda, Tendacn 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware 2024-11-21 8 High
Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac
CVE-2024-41468 2 Tenda, Tendacn 3 Fh1201, Fh1201, Fh1201 Firmware 2024-11-21 9.8 Critical
Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the cmdinput parameter at /goform/exeCommand
CVE-2024-41466 2 Tenda, Tendacn 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware 2024-11-21 7.5 High
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting.