Filtered by vendor Tenda
Subscriptions
Total
1443 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2025-9828 | 1 Tenda | 1 Cp6 | 2025-09-03 | 3.7 Low |
A vulnerability was determined in Tenda CP6 11.10.00.243. The affected element is the function sub_2B7D04 of the component uhttp. Executing manipulation can lead to risky cryptographic algorithm. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is described as difficult. The exploit has been publicly disclosed and may be utilized. | ||||
CVE-2025-55852 | 1 Tenda | 1 Ac8 | 2025-09-03 | 7.5 High |
Tenda AC8 v16.03.34.06 is vulnerable to Buffer Overflow in the formWifiBasicSet function via the parameter security or security_5g. | ||||
CVE-2025-55495 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2025-09-03 | 6.5 Medium |
Tenda AC6 V15.03.06.23_multi was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function. | ||||
CVE-2025-57217 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-09-03 | 5.3 Medium |
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler. | ||||
CVE-2025-57218 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-09-03 | 5.3 Medium |
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C. | ||||
CVE-2025-57215 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-09-03 | 7.5 High |
Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info. | ||||
CVE-2025-57219 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-09-03 | 5.3 Medium |
Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request. | ||||
CVE-2025-57220 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-09-03 | 5.3 Medium |
An input validation flaw in the 'ate' service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet. | ||||
CVE-2025-9605 | 1 Tenda | 4 Ac21, Ac21 Firmware, Ac23 and 1 more | 2025-09-03 | 9.8 Critical |
A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. | ||||
CVE-2025-9297 | 1 Tenda | 2 I22, I22 Firmware | 2025-09-03 | 8.8 High |
A vulnerability was detected in Tenda i22 1.0.0.3(4687). This impacts the function formWeixinAuthInfoGet of the file /goform/wxportalauth. Performing manipulation of the argument Type results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used. | ||||
CVE-2025-55564 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2025-09-03 | 7.5 High |
Tenda AC15 v15.03.05.19_multi_TD01 has a stack overflow via the list parameter in the fromSetIpMacBind function. | ||||
CVE-2025-55613 | 1 Tenda | 3 O3, O3 Firmware, O3v2 | 2025-09-03 | 9.8 Critical |
Tenda O3V2 1.0.0.12(3880) is vulnerable to Buffer Overflow in the fromSafeSetMacFilter function via the mac parameter. | ||||
CVE-2025-9806 | 1 Tenda | 1 F1202 | 2025-09-02 | 1.9 Low |
A vulnerability was determined in Tenda F1202 1.2.0.9/1.2.0.14/1.2.0.20. Impacted is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation with the input Fireitup causes hard-coded credentials. The attack can only be executed locally. A high degree of complexity is needed for the attack. The exploitability is considered difficult. The exploit has been publicly disclosed and may be utilized. | ||||
CVE-2025-9443 | 1 Tenda | 2 Ch22, Ch22 Firmware | 2025-09-02 | 8.8 High |
A flaw has been found in Tenda CH22 1.0.0.1. This vulnerability affects the function formeditUserName of the file /goform/editUserName. Executing manipulation of the argument new_account can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used. | ||||
CVE-2024-42987 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-09-02 | 7.5 High |
Tenda FH1206 v02.03.01.35 was discovered to contain a stack-based buffer overflow vulnerability in the fromPptpUserAdd function. The vulnerability can be triggered via the modino, username, newpwd, or pptpdnetseg parameters, all of which are passed via HTTP POST and used in unsafe sprintf calls without proper length validation. A remote attacker can exploit this flaw through a crafted POST request, which may cause a Denial of Service (DoS). In certain scenarios, this issue could potentially be leveraged to achieve remote code execution. | ||||
CVE-2025-9748 | 1 Tenda | 1 Ch22 | 2025-09-02 | 8.8 High |
A vulnerability was determined in Tenda CH22 1.0.0.1. Affected by this issue is the function fromIpsecitem of the file /goform/IPSECsave of the component httpd. Executing manipulation of the argument ipsecno can lead to stack-based buffer overflow. The attack may be performed from remote. | ||||
CVE-2025-9731 | 1 Tenda | 1 Ac9 | 2025-09-02 | 2.5 Low |
A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack's complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized. | ||||
CVE-2025-9813 | 1 Tenda | 1 Ch22 | 2025-09-02 | 8.8 High |
A vulnerability was identified in Tenda CH22 1.0.0.1. This issue affects the function formSetSambaConf of the file /goform/SetSambaConf. The manipulation of the argument samba_userNameSda leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. | ||||
CVE-2025-9791 | 1 Tenda | 1 Ac20 | 2025-09-02 | 8.8 High |
A weakness has been identified in Tenda AC20 16.03.08.05. This vulnerability affects unknown code of the file /goform/fromAdvSetMacMtuWan. This manipulation of the argument wanMTU causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be exploited. | ||||
CVE-2025-9778 | 1 Tenda | 1 W12 | 2025-09-02 | 1.9 Low |
A security vulnerability has been detected in Tenda W12 up to 3.0.0.6(3948). Affected is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. The manipulation leads to hard-coded credentials. An attack has to be approached locally. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed publicly and may be used. |