Filtered by vendor Tendacn Subscriptions
Total 157 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2017-9138 1 Tendacn 6 F1200, F1200 Firmware, F1202 and 3 more 2025-04-20 N/A
There is a debug-interface vulnerability on some Tenda routers (FH1202/F1202/F1200: versions before 1.2.0.20). After connecting locally to a router in a wired or wireless manner, one can bypass intended access restrictions by sending shell commands directly and reading their results, or by entering shell commands that change this router's username and password.
CVE-2024-33181 2 Tenda, Tendacn 3 Ac18, Ac18 Firmware, Ac18 Firmware 2025-04-07 8.8 High
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceMac parameter at ip/goform/addWifiMacFilter.
CVE-2025-29032 1 Tendacn 2 Ac9, Ac9 Firmware 2025-04-03 5.9 Medium
Tenda AC9 v15.03.05.19(6318) was discovered to contain a buffer overflow via the formWifiWpsOOB function.
CVE-2025-29357 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the startIp and endIp parameters at /goform/SetPptpServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29359 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the deviceId parameter at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29358 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the firewallEn parameter at /goform/SetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29361 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the list parameter at /goform/SetVirtualServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29360 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the time and timeZone parameters at /goform/SetSysTimeCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29362 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the list parameter at /goform/setPptpUserList. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29363 1 Tendacn 2 Rx3, Rx3 Firmware 2025-04-02 7.5 High
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to buffer overflow via the schedStartTime and schedEndTime parameters at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2024-50854 2 Tenda, Tendacn 3 G3, G3, G3 Firmware 2025-03-14 8.8 High
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a stack overflow via the formSetPortMapping function.
CVE-2024-8224 2 Tenda, Tendacn 3 G3 Firmware, G3, G3 Firmware 2024-12-13 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2764 2 Tenda, Tendacn 3 Ac10u, Ac10u Firmware, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-50853 2 Tenda, Tendacn 3 G3, G3, G3 Firmware 2024-11-21 8.8 High
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetDebugCfg function.
CVE-2024-50852 2 Tenda, Tendacn 3 G3, G3, G3 Firmware 2024-11-21 8.8 High
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetUSBPartitionUmount function.
CVE-2024-6403 1 Tendacn 2 A301, A301 Firmware 2024-11-21 6.5 Medium
A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-6402 1 Tendacn 2 A301, A301 Firmware 2024-11-21 6.5 Medium
A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-6189 1 Tendacn 2 A301, A301 Firmware 2024-11-21 8.8 High
A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-41473 2 Tenda, Tendacn 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware 2024-11-21 8 High
Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac
CVE-2024-41468 2 Tenda, Tendacn 3 Fh1201, Fh1201, Fh1201 Firmware 2024-11-21 9.8 Critical
Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the cmdinput parameter at /goform/exeCommand