Filtered by vendor
Subscriptions
Total
101 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-29880 | 1 Jetbrains | 1 Teamcity | 2024-12-16 | 4.2 Medium |
In JetBrains TeamCity before 2023.11 users with access to the agent machine might obtain permissions of the user running the agent process | ||||
CVE-2023-39470 | 1 Papercut | 1 Papercut Ng | 2024-12-05 | N/A |
PaperCut NG print.script.sandboxed Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of PaperCut NG. Authentication is required to exploit this vulnerability. The specific flaw exists within the management of the print.script.sandboxed setting. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20965. | ||||
CVE-2022-37365 | 1 Pdf-xchange | 1 Pdf-xchange Editor | 2024-11-27 | 7.8 High |
This vulnerability allows remote attackers to execute arbitrary code on affected installations of PDF-XChange Editor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the saveAs method. The application exposes a JavaScript interface that allows the attacker to write arbitrary files. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-17527. | ||||
CVE-2024-6689 | 2024-11-21 | 7.8 High | ||
Local Privilege Escalation in MSI-Installer in baramundi Management Agent v23.1.172.0 on Windows allows a local unprivileged user to escalate privileges to SYSTEM. | ||||
CVE-2024-5299 | 2024-11-21 | N/A | ||
D-Link D-View execMonitorScript Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link D-View. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the execMonitorScript method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21828. | ||||
CVE-2024-5298 | 2024-11-21 | N/A | ||
D-Link D-View queryDeviceCustomMonitorResult Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link D-View. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the queryDeviceCustomMonitorResult method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21842. | ||||
CVE-2024-35209 | 1 Siemens | 2 Sinec Traffic Analyzer, Traffic Analyzer | 2024-11-21 | 7.5 High |
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server is allowing HTTP methods like PUT and Delete. This could allow an attacker to modify unauthorized files. | ||||
CVE-2024-32764 | 2024-11-21 | 9.9 Critical | ||
A missing authentication for critical function vulnerability has been reported to affect myQNAPcloud Link. If exploited, the vulnerability could allow users with the privilege level of some functionality via a network. We have already fixed the vulnerability in the following version: myQNAPcloud Link 2.4.51 and later | ||||
CVE-2024-27444 | 2024-11-21 | 9.8 Critical | ||
langchain_experimental (aka LangChain Experimental) in LangChain before 0.1.8 allows an attacker to bypass the CVE-2023-44467 fix and execute arbitrary code via the __import__, __subclasses__, __builtins__, __globals__, __getattribute__, __bases__, __mro__, or __base__ attribute in Python code. These are not prohibited by pal_chain/base.py. | ||||
CVE-2024-27261 | 2024-11-21 | 6.4 Medium | ||
IBM Storage Defender - Resiliency Service 2.0.0 through 2.0.2 could allow a privileged user to install a potentially dangerous tar file, which could give them access to subsequent systems where the package was installed. IBM X-Force ID: 283986. | ||||
CVE-2024-1873 | 1 Lollms | 1 Lollms Web Ui | 2024-11-21 | 9.1 Critical |
parisneo/lollms-webui is vulnerable to path traversal and denial of service attacks due to an exposed `/select_database` endpoint in version a9d16b0. The endpoint improperly handles file paths, allowing attackers to specify absolute paths when interacting with the `DiscussionsDB` instance. This flaw enables attackers to create directories anywhere on the system where the application has permissions, potentially leading to denial of service by creating directories with names of critical files, such as HTTPS certificate files, causing server startup failures. Additionally, attackers can manipulate the database path, resulting in the loss of client data by constantly changing the file location to an attacker-controlled location, scattering the data across the filesystem and making recovery difficult. | ||||
CVE-2023-5389 | 1 Honeywell | 4 Controledge Unit Operations Controller, Controledge Unit Operations Controller Firmware, Controledge Virtual Unit Operations Controller and 1 more | 2024-11-21 | 9.1 Critical |
An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
CVE-2023-51584 | 2024-11-21 | N/A | ||
Voltronic Power ViewPower USBCommEx shutdown Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. User interaction is required to exploit this vulnerability in that an administrator must trigger a shutdown operation. The specific flaw exists within the shutdown method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22065. | ||||
CVE-2023-51583 | 2024-11-21 | N/A | ||
Voltronic Power ViewPower UpsScheduler Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the UpsScheduler class. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-22036. | ||||
CVE-2023-51582 | 2024-11-21 | N/A | ||
Voltronic Power ViewPower LinuxMonitorConsole Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the LinuxMonitorConsole class. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22035. | ||||
CVE-2023-51581 | 2024-11-21 | N/A | ||
Voltronic Power ViewPower MacMonitorConsole Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MacMonitorConsole class. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22034. | ||||
CVE-2023-51578 | 2024-11-21 | N/A | ||
Voltronic Power ViewPower MonitorConsole Exposed Dangerous Method Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MonitorConsole class. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-22024. | ||||
CVE-2023-51577 | 2024-11-21 | N/A | ||
Voltronic Power ViewPower setShutdown Exposed Dangerous Method Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Voltronic Power ViewPower. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the setShutdown method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-22023. | ||||
CVE-2023-51575 | 2024-11-21 | N/A | ||
Voltronic Power ViewPower MonitorConsole Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MonitorConsole class. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22011. | ||||
CVE-2023-51574 | 2024-11-21 | N/A | ||
Voltronic Power ViewPower updateManagerPassword Exposed Dangerous Method Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the updateManagerPassword method. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-22010. |