Filtered by vendor Schneider Electric
Subscriptions
Total
8 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2017-5157 | 2 Schneider-electric, Schneider Electric | 2 Homelynk Controller Lss100100, Homelynk Controller Lss100100 Firmware | 2024-11-21 | N/A |
An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code. | ||||
CVE-2014-9188 | 1 Schneider Electric | 1 Proclima | 2024-11-21 | N/A |
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers. | ||||
CVE-2014-8514 | 1 Schneider Electric | 1 Proclima | 2024-11-21 | N/A |
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers. | ||||
CVE-2014-8513 | 1 Schneider Electric | 1 Proclima | 2024-11-21 | N/A |
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers. | ||||
CVE-2014-8512 | 1 Schneider Electric | 1 Proclima | 2024-11-21 | N/A |
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers. | ||||
CVE-2013-0662 | 2 Schneider-electric, Schneider Electric | 13 Concept, Modbus Serial Driver, Modbuscommdtm Sl and 10 more | 2024-11-21 | N/A |
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. | ||||
CVE-2024-8884 | 1 Schneider Electric | 1 System Monitor Application In Harmony Industrial Pc Hmibmo Hmibmi Hmipso Hmibmp Hmibmu Hmipsp Hmipep Series | 2024-10-10 | 9.8 Critical |
CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause exposure of credentials when attacker has access to application on network over http | ||||
CVE-2024-9005 | 1 Schneider Electric | 1 Ecostruxure Power Monitoring Expert | 2024-10-10 | 7.1 High |
CWE-502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. |
Page 1 of 1.