Filtered by vendor Philips Subscriptions
Total 107 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-40704 1 Philips 1 Vue Pacs 2024-11-21 7.1 High
Philips Vue PACS uses default credentials for potentially critical functionality.
CVE-2023-40539 1 Philips 1 Vue Pacs 2024-11-21 4.4 Medium
Philips Vue PACS does not require that users have strong passwords, which could make it easier for attackers to compromise user accounts.
CVE-2023-40223 1 Philips 1 Vue Pacs 2024-11-21 4.4 Medium
Philips Vue PACS does not properly assign, modify, track, or check actor privileges, creating an unintended sphere of control for that actor.
CVE-2023-40159 1 Philips 1 Vue Pacs 2024-11-21 8.2 High
A validated user not explicitly authorized to have access to certain sensitive information could access Philips Vue PACS on the same network to expose that information.
CVE-2022-0922 1 Philips 2 E-alert, E-alert Firmware 2024-11-21 6.5 Medium
The software does not perform any authentication for critical system functionality.
CVE-2021-43552 1 Philips 1 Patient Information Center Ix 2024-11-21 6.1 Medium
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.
CVE-2021-43550 1 Philips 3 Efficia Cm, Efficia Cm Firmware, Patient Information Center Ix 2024-11-21 5.9 Medium
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.
CVE-2021-43548 1 Philips 1 Patient Information Center Ix 2024-11-21 6.5 Medium
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
CVE-2021-42744 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2024-11-21 6.2 Medium
Philips MRI 1.5T and MRI 3T Version 5.x.x exposes sensitive information to an actor not explicitly authorized to have access.
CVE-2021-39376 1 Philips 1 Tasy Electronic Medical Record 2024-11-21 8.8 High
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter.
CVE-2021-39375 1 Philips 1 Tasy Electronic Medical Record 2024-11-21 8.8 High
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the WAdvancedFilter/getDimensionItemsByCode FilterValue parameter.
CVE-2021-39369 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2024-11-21 6.5 Medium
In Philips (formerly Carestream) Vue MyVue PACS through 12.2.x.x, the VideoStream function allows Path Traversal by authenticated users to access files stored outside of the web root.
CVE-2021-33024 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2024-11-21 3.7 Low
Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval.
CVE-2021-33022 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2024-11-21 7.5 High
Philips Vue PACS versions 12.2.x.x and prior transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.
CVE-2021-33020 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2024-11-21 8.2 High
Philips Vue PACS versions 12.2.x.x and prior uses a cryptographic key or password past its expiration date, which diminishes its safety significantly by increasing the timing window for cracking attacks against that key.
CVE-2021-33018 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2024-11-21 7.5 High
The use of a broken or risky cryptographic algorithm in Philips Vue PACS versions 12.2.x.x and prior is an unnecessary risk that may result in the exposure of sensitive information.
CVE-2021-33017 1 Philips 4 Intellibridge Ec40, Intellibridge Ec40 Firmware, Intellibridge Ec80 and 1 more 2024-11-21 8.1 High
The standard access path of the IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) requires authentication, but the product has an alternate path or channel that does not require authentication.
CVE-2021-32993 1 Philips 4 Intellibridge Ec40, Intellibridge Ec40 Firmware, Intellibridge Ec80 and 1 more 2024-11-21 8.1 High
IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) contains hard-coded credentials, such as a password or a cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
CVE-2021-32966 1 Philips 1 Interoperability Solution Xds 2024-11-21 3.7 Low
Philips Interoperability Solution XDS versions 2.5 through 3.11 and 2018-1 through 2021-1 are vulnerable to clear text transmission of sensitive information when configured to use LDAP via TLS and where the domain controller returns LDAP referrals, which may allow an attacker to remotely read LDAP system credentials.
CVE-2021-27501 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2024-11-21 7.5 High
Philips Vue PACS versions 12.2.x.x and prior does not follow certain coding rules for development, which can lead to resultant weaknesses or increase the severity of the associated vulnerabilities.