Filtered by vendor Iconics
Subscriptions
Total
31 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-40264 | 1 Iconics | 1 Genesis64 | 2025-04-18 | 6.3 Medium |
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user import a project package file crafted by the attacker. | ||||
CVE-2016-2289 | 1 Iconics | 1 Webhmi | 2025-04-12 | N/A |
Directory traversal vulnerability in ICONICS WebHMI 9 and earlier allows remote attackers to read configuration files, and consequently discover password hashes, via unspecified vectors. | ||||
CVE-2011-5089 | 1 Iconics | 2 Bizviz, Genesis32 | 2025-04-11 | N/A |
Buffer overflow in the Security Login ActiveX controls in ICONICS GENESIS32 8.05, 9.0, 9.1, and 9.2 and BizViz 8.05, 9.0, 9.1, and 9.2 allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a long password. | ||||
CVE-2012-3018 | 1 Iconics | 2 Bizviz, Genesis32 | 2025-04-11 | N/A |
The lockout-recovery feature in the Security Configurator component in ICONICS GENESIS32 9.22 and earlier and BizViz 9.22 and earlier uses an improper encryption algorithm for generation of an authentication code, which allows local users to bypass intended access restrictions and obtain administrative access by predicting a challenge response. | ||||
CVE-2014-0758 | 1 Iconics | 1 Genesis32 | 2025-04-11 | N/A |
An ActiveX control in GenLaunch.htm in ICONICS GENESIS32 8.0, 8.02, 8.04, and 8.05 allows remote attackers to execute arbitrary programs via a crafted HTML document. | ||||
CVE-2011-5088 | 1 Iconics | 2 Bizviz, Genesis32 | 2025-04-11 | N/A |
The GENESIS32 IcoSetServer ActiveX control in ICONICS GENESIS32 9.21 and BizViz 9.21 configures the trusted zone on the basis of user input, which allows remote attackers to execute arbitrary code via a crafted web site, related to a "Workbench32/WebHMI component SetTrustedZone Policy vulnerability." | ||||
CVE-2011-2089 | 1 Iconics | 2 Bizviz, Genesis32 | 2025-04-11 | N/A |
Stack-based buffer overflow in the SetActiveXGUID method in the VersionInfo ActiveX control in GenVersion.dll 8.0.138.0 in the WebHMI subsystem in ICONICS BizViz 9.x before 9.22 and GENESIS32 9.x before 9.22 allows remote attackers to execute arbitrary code via a long string in the argument. NOTE: some of these details are obtained from third party information. | ||||
CVE-2006-6488 | 1 Iconics | 1 Dialog Wrapper Module Activex Control | 2025-04-09 | N/A |
Stack-based buffer overflow in the DoModal function in the Dialog Wrapper Module ActiveX control (DlgWrapper.dll) before 8.4.166.0, as used by ICONICS OPC Enabled Gauge, Switch, and Vessel ActiveX, allows remote attackers to execute arbitrary code via a long (1) FileName or (2) Filter argument. | ||||
CVE-2024-26314 | 3 Iconics, Jungo, Mitsubishielectric | 49 Genesis64, Windriver, C Controller Module Setting And Monitoring Tool and 46 more | 2025-03-22 | 7.8 High |
Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code. | ||||
CVE-2024-9852 | 2 Iconics, Mitsubishielectric | 3 Genesis64, Genesis64, Mc Works64 | 2024-12-06 | 7.8 High |
Uncontrolled Search Path Element vulnerability in ICONICS GENESIS64 all versions, Mitsubishi Electric GENESIS64 all versions and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products. | ||||
CVE-2024-8300 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Genesis64 | 2024-12-06 | 7 High |
Dead Code vulnerability in ICONICS GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 and Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products. | ||||
CVE-2024-8299 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-12-06 | 7.8 High |
Uncontrolled Search Path Element vulnerability in ICONICS GENESIS64 all versions, Mitsubishi Electric GENESIS64 all versions and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products. | ||||
CVE-2022-33320 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-11-21 | 7.8 High |
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes. | ||||
CVE-2022-33319 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-11-21 | 9.1 Critical |
Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server. | ||||
CVE-2022-33318 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-11-21 | 9.8 Critical |
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64 server. | ||||
CVE-2022-33317 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-11-21 | 7.8 High |
Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes. | ||||
CVE-2022-33316 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-11-21 | 7.8 High |
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. | ||||
CVE-2022-33315 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-11-21 | 7.8 High |
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. | ||||
CVE-2022-29834 | 1 Iconics | 1 Genesis64 | 2024-11-21 | 7.5 High |
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS GENESIS64 versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 mobile monitoring application and accessing the monitoring screen. | ||||
CVE-2022-23130 | 2 Iconics, Mitsubishielectric | 3 Genesis64, Hyper Historian, Mc Works64 | 2024-11-21 | 5.5 Medium |
Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.97 and prior and ICONICS Hyper Historian versions 10.97 and prior allows an attacker to cause a DoS condition in the database server by getting a legitimate user to import a configuration file containing specially crafted stored procedures into GENESIS64 or MC Works64 and execute commands against the database from GENESIS64 or MC Works64. |