Filtered by vendor Tenda
Subscriptions
Filtered by product Rx9 Pro
Subscriptions
Total
9 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-43886 | 1 Tenda | 2 Rx9 Pro, Rx9 Pro Firmware | 2024-11-21 | 7.1 High |
A buffer overflow in the HTTP server component of Tenda RX9 Pro v22.03.02.20 might allow an authenticated attacker to overwrite memory. | ||||
CVE-2023-43885 | 1 Tenda | 2 Rx9 Pro, Rx9 Pro Firmware | 2024-11-21 | 8.1 High |
Missing error handling in the HTTP server component of Tenda RX9 Pro Firmware V22.03.02.20 allows authenticated attackers to arbitrarily lock the device. | ||||
CVE-2022-38831 | 1 Tenda | 2 Rx9 Pro, Rx9 Pro Firmware | 2024-11-21 | 9.8 Critical |
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/SetNetControlList | ||||
CVE-2022-38830 | 1 Tenda | 2 Rx9 Pro, Rx9 Pro Firmware | 2024-11-21 | 9.8 Critical |
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setIPv6Status. | ||||
CVE-2022-38829 | 1 Tenda | 2 Rx9 Pro, Rx9 Pro Firmware | 2024-11-21 | 9.8 Critical |
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg. | ||||
CVE-2024-10351 | 1 Tenda | 2 Rx9 Pro, Rx9 Pro Firmware | 2024-11-01 | 8.8 High |
A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2024-10283 | 1 Tenda | 3 Rx9, Rx9 Pro, Rx9 Pro Firmware | 2024-11-01 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2024-10281 | 1 Tenda | 3 Rx9, Rx9 Pro, Rx9 Pro Firmware | 2024-11-01 | 8.8 High |
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2024-10282 | 1 Tenda | 3 Rx9, Rx9 Pro, Rx9 Pro Firmware | 2024-11-01 | 8.8 High |
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. |
Page 1 of 1.