Filtered by vendor Tenda Subscriptions
Filtered by product Ac18 Firmware Subscriptions
Total 78 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2017-16936 1 Tenda 6 Ac15, Ac15 Firmware, Ac18 and 3 more 2025-04-20 N/A
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring.
CVE-2017-16923 1 Tenda 6 Ac15, Ac15 Firmware, Ac18 and 3 more 2025-04-20 N/A
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input.
CVE-2024-2489 1 Tenda 2 Ac18, Ac18 Firmware 2025-04-10 8.8 High
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-30891 1 Tenda 2 Ac18, Ac18 Firmware 2025-04-10 8.8 High
A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution.
CVE-2024-33835 1 Tenda 2 Ac18, Ac18 Firmware 2025-04-10 9.8 Critical
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.
CVE-2024-33181 2 Tenda, Tendacn 3 Ac18, Ac18 Firmware, Ac18 Firmware 2025-04-07 8.8 High
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceMac parameter at ip/goform/addWifiMacFilter.
CVE-2024-41630 1 Tenda 2 Ac18, Ac18 Firmware 2025-04-07 7.6 High
Stack-based buffer overflow vulnerability in Tenda AC18 V15.03.3.10_EN allows a remote attacker to execute arbitrary code via the ssid parameter at ip/goform/fast_setting_wifi_set.
CVE-2023-24170 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-28 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/fromSetWirelessRepeat.
CVE-2023-24169 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-28 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c.
CVE-2023-24167 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-28 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node.
CVE-2023-24166 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-28 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet.
CVE-2023-24165 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-28 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo.
CVE-2023-24164 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-28 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318.
CVE-2024-57582 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-22 9.8 Critical
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the startIP parameter in the formSetPPTPServer function.
CVE-2024-57579 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-20 9.8 Critical
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp parameter in the formSetClientState function.
CVE-2024-57581 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-18 9.8 Critical
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
CVE-2024-57580 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-18 9.8 Critical
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
CVE-2024-57578 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-17 5.7 Medium
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the funcpara1 parameter in the formSetCfm function.
CVE-2024-57577 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-17 5.7 Medium
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2024-34974 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-17 8.2 High
Tenda AC18 v15.03.05.19 is vulnerable to Buffer Overflow in the formSetPPTPServer function via the endIp parameter.