Filtered by vendor Tenda
Subscriptions
Filtered by product Ac18 Firmware
Subscriptions
Total
78 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2017-16936 | 1 Tenda | 6 Ac15, Ac15 Firmware, Ac18 and 3 more | 2025-04-20 | N/A |
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring. | ||||
CVE-2017-16923 | 1 Tenda | 6 Ac15, Ac15 Firmware, Ac18 and 3 more | 2025-04-20 | N/A |
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input. | ||||
CVE-2024-2489 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-10 | 8.8 High |
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-30891 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-10 | 8.8 High |
A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution. | ||||
CVE-2024-33835 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-10 | 9.8 Critical |
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function. | ||||
CVE-2024-33181 | 2 Tenda, Tendacn | 3 Ac18, Ac18 Firmware, Ac18 Firmware | 2025-04-07 | 8.8 High |
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceMac parameter at ip/goform/addWifiMacFilter. | ||||
CVE-2024-41630 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-07 | 7.6 High |
Stack-based buffer overflow vulnerability in Tenda AC18 V15.03.3.10_EN allows a remote attacker to execute arbitrary code via the ssid parameter at ip/goform/fast_setting_wifi_set. | ||||
CVE-2023-24170 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | 9.8 Critical |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/fromSetWirelessRepeat. | ||||
CVE-2023-24169 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | 9.8 Critical |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c. | ||||
CVE-2023-24167 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | 9.8 Critical |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node. | ||||
CVE-2023-24166 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | 9.8 Critical |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet. | ||||
CVE-2023-24165 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | 9.8 Critical |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo. | ||||
CVE-2023-24164 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | 9.8 Critical |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318. | ||||
CVE-2024-57582 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-22 | 9.8 Critical |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the startIP parameter in the formSetPPTPServer function. | ||||
CVE-2024-57579 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-20 | 9.8 Critical |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp parameter in the formSetClientState function. | ||||
CVE-2024-57581 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-18 | 9.8 Critical |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. | ||||
CVE-2024-57580 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-18 | 9.8 Critical |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function. | ||||
CVE-2024-57578 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-17 | 5.7 Medium |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the funcpara1 parameter in the formSetCfm function. | ||||
CVE-2024-57577 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-17 | 5.7 Medium |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | ||||
CVE-2024-34974 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-17 | 8.2 High |
Tenda AC18 v15.03.05.19 is vulnerable to Buffer Overflow in the formSetPPTPServer function via the endIp parameter. |