CVE-2019-6535 1 Mitsubishielectric 36 Q03udecpu, Q03udecpu Firmware, Q03udvcpu and 33 more 2024-11-21 7.5 High
Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash.
CVE-2019-14931 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 9.8 Critical
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's system shell. Functionality in mobile.php provides users with the ability to ping sites or IP addresses via Mobile Connection Test. When the Mobile Connection Test is submitted, action.php is called to execute the test. An attacker can use a shell command separator (;) in the host variable to execute operating system commands upon submitting the test data.
CVE-2019-14930 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 9.8 Critical
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are able to escalate privileges to root without supplying a password due to insecure entries in /etc/sudoers on the RTU.)
CVE-2019-14929 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 9.8 Critical
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. An unauthenticated user can obtain the exposed password credentials to gain access to the following services: DDNS service, Mobile Network Provider, and OpenVPN service.
CVE-2019-14928 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 5.4 Medium
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to stored XSS is SerialInitialModemString in the index.php page.
CVE-2019-14927 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 7.5 High
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).
CVE-2019-14926 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 9.8 Critical
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware updates. In other words, these devices use private-key values in /etc/ssh/ssh_host_rsa_key, /etc/ssh/ssh_host_ecdsa_key, and /etc/ssh/ssh_host_dsa_key files that are publicly available from the vendor web sites.
CVE-2019-14925 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 6.5 Medium
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.
CVE-2019-13555 1 Mitsubishielectric 20 L02\/06\/26cpu, L02\/06\/26cpu-cm, L02\/06\/26cpu-cm Firmware and 17 more 2024-11-21 5.9 Medium
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior, L02/06/26CPU-P, L26CPU-PBT: serial number 21101 and prior, and L02/06/26CPU-CM, L26CPU-BT-CM: serial number 21101 and prior, a remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules.
CVE-2019-10977 1 Mitsubishielectric 2 Qj71e71-100, Qj71e71-100 Firmware 2024-11-21 7.5 High
In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.
CVE-2019-10976 1 Mitsubishielectric 2 Electric Fr Configurator2, Electric Fr Configurator2 Firmware 2024-11-21 N/A
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user opens the file, the attacker could read arbitrary files.
CVE-2019-10972 1 Mitsubishielectric 1 Electric Fr Configurator2 2024-11-21 5.5 Medium
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.
CVE-2018-16061 1 Mitsubishielectric 2 Smartrtu, Smartrtu Firmware 2024-11-21 6.1 Medium
Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php.
CVE-2018-16060 1 Mitsubishielectric 2 Smartrtu, Smartrtu Firmware 2024-11-21 7.5 High
Mitsubishi Electric Europe B.V. SmartRTU devices allow remote attackers to obtain sensitive information (directory listing and source code) via a direct request to the /web URI.
CVE-2017-9638 1 Mitsubishielectric 1 E-designer 2024-11-21 N/A
Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.
CVE-2017-9636 1 Mitsubishielectric 1 E-designer 2024-11-21 N/A
Mitsubishi E-Designer, Version 7.52 Build 344 contains five code sections which may be exploited to overwrite the heap. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.
CVE-2017-9634 1 Mitsubishielectric 1 E-designer 2024-11-21 N/A
Mitsubishi E-Designer, Version 7.52 Build 344 contains two code sections which may be exploited to allow an attacker to overwrite arbitrary memory locations. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.
CVE-2016-8370 1 Mitsubishielectric 6 Qj71e71-100, Qj71e71-100 Firmware, Qj71e71-b2 and 3 more 2024-11-21 7.5 High
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.
CVE-2016-8368 1 Mitsubishielectric 6 Qj71e71-100, Qj71e71-100 Firmware, Qj71e71-b2 and 3 more 2024-11-21 8.6 High
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock.
CVE-2013-2817 1 Mitsubishielectric 1 Mc-worx Suite 2024-11-21 N/A
An ActiveX control in IcoLaunch.dll in Mitsubishi Electric Automation MC-WorX Suite 8.02 allows user-assisted remote attackers to execute arbitrary programs via a crafted HTML document in conjunction with a Login Client button click.