Filtered by CWE-259
Filtered by vendor Subscriptions
Total 101 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-41713 1 Sonicwall 61 Nsa2700, Nsa3700, Nsa4700 and 58 more 2024-11-21 7.5 High
SonicOS Use of Hard-coded Password vulnerability in the 'dynHandleBuyToolbar' demo function.
CVE-2023-41030 1 Juplink 2 Rx4-1500, Rx4-1500 Firmware 2024-11-21 6.3 Medium
Hard-coded credentials in Juplink RX4-1500 versions V1.0.2 through V1.0.5 allow unauthenticated attackers to log in to the web interface or telnet service as the 'user' user.
CVE-2023-3237 1 Otcms 1 Otcms 2024-11-21 6.3 Medium
A vulnerability classified as critical was found in OTCMS up to 6.62. This vulnerability affects unknown code. The manipulation of the argument username/password with the input admin leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-231508.
CVE-2023-32145 1 D-link 1 Dap-1360 2024-11-21 N/A
D-Link DAP-1360 Hardcoded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DAP-1360 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of login requests to the web-based user interface. The firmware contains hard-coded default credentials. An attacker can leverage this vulnerability to bypass authentication on the system. . Was ZDI-CAN-18455.
CVE-2023-2645 1 Usr 2 Usr-g806, Usr-g806 Firmware 2024-11-21 9.8 Critical
A vulnerability, which was classified as critical, was found in USR USR-G806 1.0.41. Affected is an unknown function of the component Web Management Page. The manipulation of the argument username/password with the input root leads to use of hard-coded password. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. VDB-228774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-2061 1 Mitsubishielectric 8 Fx5-enet\/ip, Fx5-enet\/ip Firmware, Rj71eip91 and 5 more 2024-11-21 6.2 Medium
Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access to the module via FTP.
CVE-2023-29103 1 Siemens 4 6gk1411-1ac00, 6gk1411-1ac00 Firmware, 6gk1411-5ac00 and 1 more 2024-11-21 4.3 Medium
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data.
CVE-2023-23771 1 Motorola 2 Mbts Base Radio, Mbts Base Radio Firmware 2024-11-21 8.4 High
Motorola MBTS Base Radio accepts hard-coded backdoor password. The Motorola MBTS Base Radio Man Machine Interface (MMI), allowing for service technicians to diagnose and configure the device, accepts a hard-coded backdoor password that cannot be changed or disabled.
CVE-2023-23770 1 Motorola 2 Mbts Site Controller, Mbts Site Controller Firmware 2024-11-21 9.4 Critical
Motorola MBTS Site Controller accepts hard-coded backdoor password. The Motorola MBTS Site Controller Man Machine Interface (MMI), allowing for service technicians to diagnose and configure the device, accepts a hard-coded backdoor password that cannot be changed or disabled.
CVE-2023-1944 1 Kubernetes 1 Minikube 2024-11-21 8.4 High
This vulnerability enables ssh access to minikube container using a default password.
CVE-2023-0808 3 Bosswerk, Deyeinverter, Revolt-power 6 Inverter, Inverter Firmware, Inverter and 3 more 2024-11-21 3.9 Low
A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability.
CVE-2022-45444 1 Sewio 1 Real-time Location System Studio 2024-11-21 10 Critical
Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 contains hard-coded passwords for select users in the application’s database. This could allow a remote attacker to login to the database with unrestricted access.
CVE-2022-41653 1 Daikinlatam 2 Svmpc1, Svmpc2 2024-11-21 9.8 Critical
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system.
CVE-2022-30271 1 Motorola 2 Ace1000, Ace1000 Firmware 2024-11-21 9.8 Critical
The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default.
CVE-2022-29831 1 Mitsubishielectric 1 Gx Works3 2024-11-21 7.5 High
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.
CVE-2022-29825 1 Mitsubishielectric 1 Gx Works3 2024-11-21 5.6 Medium
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
CVE-2022-27172 1 Inhandnetworks 2 Ir302, Ir302 Firmware 2024-11-21 8.8 High
A hard-coded password vulnerability exists in the console infactory functionality of InHand Networks InRouter302 V3.5.37. A specially-crafted network request can lead to privileged operation execution. An attacker can send a sequence of requests to trigger this vulnerability.
CVE-2022-22144 1 Tcl 1 Linkhub Mesh Wifi Ac1200 2024-11-21 9.8 Critical
A hard-coded password vulnerability exists in the libcommonprod.so prod_change_root_passwd functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. During system startup this functionality is always called, leading to a known root password. An attacker does not have to do anything to trigger this vulnerability.
CVE-2021-38456 1 Moxa 1 Mxview 2024-11-21 9.8 Critical
A use of hard-coded password vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to gain access through accounts using default passwords
CVE-2021-36312 1 Dell 1 Cloudlink 2024-11-21 9.1 Critical
Dell EMC CloudLink 7.1 and all prior versions contain a Hard-coded Password Vulnerability. A remote high privileged attacker, with the knowledge of the hard-coded credentials, may potentially exploit this vulnerability to gain unauthorized access to the system.