Filtered by vendor Siemens
Subscriptions
Total
2125 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-39869 | 1 Siemens | 1 Sinema Remote Connect Server | 2025-08-27 | 6.5 Medium |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected products allow to upload certificates. An authenticated attacker could upload a crafted certificates leading to a permanent denial-of-service situation. In order to recover from such an attack, the offending certificate needs to be removed manually. | ||||
CVE-2024-39868 | 1 Siemens | 1 Sinema Remote Connect Server | 2025-08-27 | 7.6 High |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges. | ||||
CVE-2024-39867 | 1 Siemens | 1 Sinema Remote Connect Server | 2025-08-27 | 7.6 High |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges. | ||||
CVE-2024-39866 | 1 Siemens | 1 Sinema Remote Connect Server | 2025-08-27 | 8.8 High |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges. | ||||
CVE-2024-39865 | 1 Siemens | 1 Sinema Remote Connect Server | 2025-08-27 | 8.8 High |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker with access to the backup encryption key to upload malicious files, that could potentially lead to remote code execution. | ||||
CVE-2024-39675 | 1 Siemens | 24 Ruggedcom Ros Rmc30, Ruggedcom Ros Rmc30nc, Ruggedcom Ros Rp110 and 21 more | 2025-08-27 | 8.8 High |
A vulnerability has been identified in RUGGEDCOM RMC30 (All versions < V4.3.10), RUGGEDCOM RMC30NC (All versions < V4.3.10), RUGGEDCOM RP110 (All versions < V4.3.10), RUGGEDCOM RP110NC (All versions < V4.3.10), RUGGEDCOM RS400 (All versions < V4.3.10), RUGGEDCOM RS400NC (All versions < V4.3.10), RUGGEDCOM RS401 (All versions < V4.3.10), RUGGEDCOM RS401NC (All versions < V4.3.10), RUGGEDCOM RS416 (All versions < V4.3.10), RUGGEDCOM RS416NC (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416P (All versions < V4.3.10), RUGGEDCOM RS416PNC (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416v2 V5.X (All versions < V5.9.0), RUGGEDCOM RS910 (All versions < V4.3.10), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910LNC (All versions), RUGGEDCOM RS910NC (All versions < V4.3.10), RUGGEDCOM RS910W (All versions < V4.3.10), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920LNC (All versions), RUGGEDCOM RS920W (All versions). In some configurations the affected products wrongly enable the Modbus service in non-managed VLANS. Only serial devices are affected by this vulnerability. | ||||
CVE-2024-39571 | 1 Siemens | 1 Sinema Remote Connect Server | 2025-08-27 | 8.8 High |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges. | ||||
CVE-2024-39570 | 1 Siemens | 1 Sinema Remote Connect Server | 2025-08-27 | 8.8 High |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code with root privileges. | ||||
CVE-2024-39569 | 1 Siemens | 1 Sinema Remote Connect Client | 2025-08-27 | 6.6 Medium |
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an administrative remote attacker running a corresponding SINEMA Remote Connect Server to execute arbitrary code with system privileges on the client system. | ||||
CVE-2024-39568 | 1 Siemens | 1 Sinema Remote Connect Client | 2025-08-27 | 7.8 High |
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading proxy configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges. | ||||
CVE-2024-39567 | 1 Siemens | 1 Sinema Remote Connect Client | 2025-08-27 | 7.8 High |
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges. | ||||
CVE-2024-38278 | 1 Siemens | 32 Ruggedcom Ros Rmc8388, Ruggedcom Ros Rmc8388nc, Ruggedcom Ros Rs416ncv2 and 29 more | 2025-08-27 | 6.6 Medium |
A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.9.0), RUGGEDCOM RMC8388NC V5.X (All versions < V5.9.0), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416v2 V5.X (All versions < V5.9.0), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900GNC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900NC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100NC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100PNC (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2288 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2288NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300P V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300PNC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2488 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2488NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG907R (All versions < V5.9.0), RUGGEDCOM RSG908C (All versions < V5.9.0), RUGGEDCOM RSG909R (All versions < V5.9.0), RUGGEDCOM RSG910C (All versions < V5.9.0), RUGGEDCOM RSG920P V5.X (All versions < V5.9.0), RUGGEDCOM RSG920PNC V5.X (All versions < V5.9.0), RUGGEDCOM RSL910 (All versions < V5.9.0), RUGGEDCOM RSL910NC (All versions < V5.9.0), RUGGEDCOM RST2228 (All versions < V5.9.0), RUGGEDCOM RST2228P (All versions < V5.9.0), RUGGEDCOM RST916C (All versions < V5.9.0), RUGGEDCOM RST916P (All versions < V5.9.0). The affected products with IP forwarding enabled wrongly make available certain remote services in non-managed VLANs, even if these services are not intentionally activated. An attacker could leverage this vulnerability to create a remote shell to the affected system. | ||||
CVE-2024-37997 | 1 Siemens | 2 Jt Open, Plm Xml Sdk | 2025-08-27 | 7.8 High |
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2024-32057 | 1 Siemens | 3 Ps\/iges Parasolid Translator, Ps Iges Parasolid Translator Component, Simcenter Femap | 2025-08-27 | 7.8 High |
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains a type confusion vulnerability while parsing IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21562) | ||||
CVE-2024-32056 | 1 Siemens | 1 Simcenter Femap | 2025-08-27 | 7.8 High |
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS part file. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2024-32055 | 1 Siemens | 3 Ps\/iges Parasolid Translator, Ps Iges Parasolid Translator Component, Simcenter Femap | 2025-08-27 | 7.8 High |
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2024-30321 | 1 Siemens | 3 Simatic Pcs 7, Simatic Wincc, Simatic Wincc Runtime Professional | 2025-08-27 | 5.9 Medium |
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 23), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly handle certain requests to their web application, which may lead to the leak of privileged information. This could allow an unauthenticated remote attacker to retrieve information such as users and passwords. | ||||
CVE-2023-7066 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2025-08-27 | 7.8 High |
The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2023-52891 | 1 Siemens | 6 Simatic Energy Manager Basic, Simatic Energy Manager Pro, Simatic Ipc Diagbase and 3 more | 2025-08-27 | 5.3 Medium |
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. | ||||
CVE-2023-52238 | 1 Siemens | 2 Ruggedcom Rst2228, Ruggedcom Rst2228p | 2025-08-27 | 4.3 Medium |
A vulnerability has been identified in RUGGEDCOM RST2228 (All versions < V5.9.0), RUGGEDCOM RST2228P (All versions < V5.9.0). The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients. |