Filtered by vendor Sick Subscriptions
Total 72 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-43698 1 Sick 2 Apu0200, Apu0200 Firmware 2024-11-21 7.1 High
Improper Neutralization of Input During Web Page Generation (’Cross-site Scripting’) in RDT400 in SICK APU allows an unprivileged remote attacker to run arbitrary code in the clients browser via injecting code into the website.
CVE-2023-43696 1 Sick 2 Apu0200, Apu0200 Firmware 2024-11-21 8.2 High
Improper Access Control in SICK APU allows an unprivileged remote attacker to download as well as upload arbitrary files via anonymous access to the FTP server.
CVE-2023-3273 2 Sick, Sick Ag 3 Icr890-4, Icr890-4 Firmware, Icr890-4 2024-11-21 7.5 High
Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to affect the availability of the device by changing settings of the device such as the IP address based on missing access control.
CVE-2023-3272 2 Sick, Sick Ag 3 Icr890-4, Icr890-4 Firmware, Icr890-4 2024-11-21 7.5 High
Cleartext Transmission of Sensitive Information in the SICK ICR890-4 could allow a remote attacker to gather sensitive information by intercepting network traffic that is not encrypted.
CVE-2023-3271 2 Sick, Sick Ag 3 Icr890-4, Icr890-4 Firmware, Icr890-4 2024-11-21 8.2 High
Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to gather information about the system and download data via the REST API by accessing unauthenticated endpoints.
CVE-2023-3270 2 Sick, Sick Ag 3 Icr890-4, Icr890-4 Firmware, Icr890-4 2024-11-21 8.6 High
Exposure of Sensitive Information to an Unauthorized Actor in the SICK ICR890-4 could allow an unauthenticated remote attacker to retrieve sensitive information about the system.
CVE-2023-35699 1 Sick 2 Icr890-4, Icr890-4 Firmware 2024-11-21 5.3 Medium
Cleartext Storage on Disk in the SICK ICR890-4 could allow an unauthenticated attacker with local access to the device to disclose sensitive information by accessing a SD card.
CVE-2023-35698 1 Sick 2 Icr890-4, Icr890-4 Firmware 2024-11-21 5.3 Medium
Observable Response Discrepancy in the SICK ICR890-4 could allow a remote attacker to identify valid usernames for the FTP server from the response given during a failed login attempt.
CVE-2023-35697 2 Sick, Sick Ag 3 Icr890-4, Icr890-4 Firmware, Icr890-4 2024-11-21 5.3 Medium
Improper Restriction of Excessive Authentication Attempts in the SICK ICR890-4 could allow a remote attacker to brute-force user credentials.
CVE-2023-35696 2 Sick, Sick Ag 3 Icr890-4, Icr890-4 Firmware, Icr890-4 2024-11-21 7.5 High
Unauthenticated endpoints in the SICK ICR890-4 could allow an unauthenticated remote attacker to retrieve sensitive information about the device via HTTP requests.
CVE-2023-31409 1 Sick 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more 2024-11-21 5.3 Medium
Uncontrolled Resource Consumption in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an remote attacker to influence the availability of the webserver by invocing a Slowloris style attack via HTTP requests.
CVE-2023-31408 1 Sick 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more 2024-11-21 5.3 Medium
Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to potentially steal user credentials that are stored in the user’s browsers local storage via cross-site-scripting attacks.
CVE-2023-23453 1 Sick 4 Fx0-gent00000, Fx0-gent00000 Firmware, Fx0-gent00010 and 1 more 2024-11-21 9.8 Critical
Missing Authentication for Critical Function in SICK FX0-GENT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
CVE-2023-23452 1 Sick 4 Fx0-gpnt00000, Fx0-gpnt00000 Firmware, Fx0-gpnt00010 and 1 more 2024-11-21 9.8 Critical
Missing Authentication for Critical Function in SICK FX0-GPNT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
CVE-2023-23451 1 Sick 20 Fx0-gent00000, Fx0-gent00000 Firmware, Fx0-gent00030 and 17 more 2024-11-21 9.8 Critical
The Flexi Classic and Flexi Soft Gateways SICK UE410-EN3 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN1 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN3S04 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN4 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK FX0-GENT00000 FLEXISOFT EIP GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GMOD00000 FLEXISOFT MOD GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GPNT00000 FLEXISOFT PNET GATEW. with serial number <=2311xxxx with Firmware <=V2.12.0, SICK FX0-GENT00030 FLEXISOFT EIP GATEW.V2 with serial number <=2311xxxx all Firmware versions, SICK FX0-GPNT00030 FLEXISOFT PNET GATEW.V2 with serial number <=2311xxxx all Firmware versions and SICK FX0-GMOD00010 FLEXISOFT MOD GW with serial number <=2311xxxx with Firmware <=V2.11.0 all have Telnet enabled by factory default. No password is set in the default configuration.
CVE-2023-23450 1 Sick 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more 2024-11-21 6.2 Medium
Use of Password Hash Instead of Password for Authentication in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to use a password hash instead of an actual password to login to a valid user account via the REST interface.
CVE-2023-23449 1 Sick 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more 2024-11-21 5.3 Medium
Observable Response Discrepancy in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to gain information about valid usernames by analyzing challenge responses from the server via the REST interface.
CVE-2023-23448 1 Sick 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more 2024-11-21 5.3 Medium
Inclusion of Sensitive Information in Source Code in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to gain information about valid usernames via analysis of source code.
CVE-2023-23447 1 Sick 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more 2024-11-21 7.5 High
Uncontrolled Resource Consumption in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to influence the availability of the webserver by invocing several open file requests via the REST interface.
CVE-2023-23446 1 Sick 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more 2024-11-21 7.5 High
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to download files by using a therefore unpriviledged account via the REST interface.