Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-10774", "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988", "state": "PUBLISHED", "assignerShortName": "SICK AG", "dateReserved": "2024-11-04T13:07:02.373Z", "datePublished": "2024-12-06T12:35:03.327Z", "dateUpdated": "2024-12-09T14:48:43.228Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "SICK InspectorP61x", "vendor": "SICK AG", "versions": [{"lessThan": "<5.0.0", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "SICK InspectorP62x", "vendor": "SICK AG", "versions": [{"lessThan": "<5.0.0", "status": "affected", "version": "0", "versionType": "custom"}]}], "credits": [{"lang": "en", "type": "finder", "value": "Manuel Stotz"}, {"lang": "en", "type": "finder", "value": "Tobias Jaeger"}], "datePublic": "2024-12-06T12:00:00.000Z", "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication."}], "value": "Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988", "shortName": "SICK AG", "dateUpdated": "2024-12-06T12:35:03.327Z"}, "references": [{"tags": ["x_SICK PSIRT Website"], "url": "https://sick.com/psirt"}, {"tags": ["x_SICK Operating Guidelines"], "url": "https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF"}, {"tags": ["x_ICS-CERT recommended practices on Industrial Security"], "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"}, {"tags": ["x_CVSS v3.1 Calculator"], "url": "https://www.first.org/cvss/calculator/3.1"}, {"tags": ["vendor-advisory"], "url": "https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0006.pdf"}, {"tags": ["vendor-advisory", "x_csaf"], "url": "https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0006.json"}], "source": {"advisory": "SCA-2024-0006", "discovery": "EXTERNAL"}, "title": "SICK InspectorP61x and SICK InspectorP62x have unauthenticated CROWN APIs", "workarounds": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "For InspectorP61x and InspectorP62x: \n\nCustomers are strongly recommended to upgrade to the latest release. Furthermore, the\napp development for which the CROWN API is required should be done in a trusted environment. As\nsoon as the device is used productively with the custom-developed apps, the CROWN API should be\ndeactivated."}], "value": "For InspectorP61x and InspectorP62x: \n\nCustomers are strongly recommended to upgrade to the latest release. Furthermore, the\napp development for which the CROWN API is required should be done in a trusted environment. As\nsoon as the device is used productively with the custom-developed apps, the CROWN API should be\ndeactivated."}], "x_generator": {"engine": "Vulnogram 0.2.0"}}, "adp": [{"affected": [{"vendor": "sick", "product": "inspector61x_firmware", "cpes": ["cpe:2.3:o:sick:inspector61x_firmware:-:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "0", "status": "affected", "lessThan": "5.0.0", "versionType": "custom"}]}, {"vendor": "sick", "product": "inspector62x_firmware", "cpes": ["cpe:2.3:o:sick:inspector62x_firmware:-:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "0", "status": "affected", "lessThan": "5.0.0", "versionType": "custom"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-12-09T14:47:57.127996Z", "id": "CVE-2024-10774", "options": [{"Exploitation": "none"}, {"Automatable": "yes"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-12-09T14:48:43.228Z"}}]}}