Filtered by vendor Tenda Subscriptions
Total 938 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2024-8224 2 Tenda, Tendacn 3 G3 Firmware, G3, G3 Firmware 2024-12-13 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-44387 1 Tenda 2 Fh1206, Fh1206 Firmware 2024-12-13 6.5 Medium
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet.
CVE-2024-44390 1 Tenda 2 Fh1206, Fh1206 Firmware 2024-12-13 8 High
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset.
CVE-2024-36604 1 Tenda 2 O3, O3 Firmware 2024-12-13 9.8 Critical
Tenda O3V2 v1.0.0.12(3880) was discovered to contain a Blind Command Injection via stpEn parameter in the SetStp function. This vulnerability allows attackers to execute arbitrary commands with root privileges.
CVE-2024-2764 2 Tenda, Tendacn 3 Ac10u, Ac10u Firmware, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2763 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2711 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2710 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2709 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2708 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2707 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 6.3 Medium
A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2706 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2705 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2704 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2703 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-12002 1 Tenda 8 Fh1201, Fh1201 Firmware, Fh1202 and 5 more 2024-12-11 4.3 Medium
A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2022-40010 1 Tenda 2 Ac6, Ac6 Firmware 2024-12-05 5.4 Medium
Tenda AC6 AC1200 Smart Dual-Band WiFi Router 15.03.06.50_multi was discovered to contain a cross-site scripting (XSS) vulnerability via the deviceId parameter in the Parental Control module.
CVE-2024-11745 1 Tenda 2 Ac8, Ac8 Firmware 2024-12-03 8.8 High
A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2023-49046 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-11-26 9.8 Critical
Stack Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the devName parameter in the function formAddMacfilterRule.
CVE-2023-49432 1 Tenda 2 Ax9, Ax9 Firmware 2024-11-26 9.8 Critical
Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'deviceList' parameter at /goform/setMacFilterCfg.