In Eclipse BaSyx Go Components versions up to and including 1.1.2, ABAC-enabled deployments of the Submodel Repository and the AAS Environment return Submodel Elements that the caller is not authorized to read from `GET /submodels/{submodelIdentifier}/submodel-elements`.
If an access rule grants READ on a single Submodel Element through a `$sme` `REFERABLE` object, the list route returns every element of that Submodel, including its value, as soon as one element matches the caller's rules. The single-element route and the full Submodel read enforce the same rule and deny access to the other elements. An authenticated caller with a READ grant for one element of a Submodel can therefore read all other elements of that Submodel.
The issue is fixed in Eclipse BaSyx Go Components v1.1.3.
Metrics
Affected Vendors & Products
References
History
Sat, 14 Nov 2026 16:45:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Title | Partial Read Access Bypass in Eclipse BaSyx Go Components Submodel Repository |
Sat, 14 Nov 2026 08:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Title | Partial Read Access Bypass in Eclipse BaSyx Go Components Submodel Repository |
Fri, 13 Nov 2026 23:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Eclipse
Eclipse eclipse Basyx Go Components |
|
| Vendors & Products |
Eclipse
Eclipse eclipse Basyx Go Components |
Fri, 13 Nov 2026 14:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | In Eclipse BaSyx Go Components versions up to and including 1.1.2, ABAC-enabled deployments of the Submodel Repository and the AAS Environment return Submodel Elements that the caller is not authorized to read from `GET /submodels/{submodelIdentifier}/submodel-elements`. If an access rule grants READ on a single Submodel Element through a `$sme` `REFERABLE` object, the list route returns every element of that Submodel, including its value, as soon as one element matches the caller's rules. The single-element route and the full Submodel read enforce the same rule and deny access to the other elements. An authenticated caller with a READ grant for one element of a Submodel can therefore read all other elements of that Submodel. The issue is fixed in Eclipse BaSyx Go Components v1.1.3. | |
| Weaknesses | CWE-200 CWE-863 |
|
| References |
|
|
| Metrics |
cvssV4_0
|
Status: PUBLISHED
Assigner: eclipse
Published: 2026-11-13T14:22:11.926Z
Updated: 2026-11-13T14:22:11.926Z
Reserved: 2026-11-12T14:43:27.773Z
Link: CVE-2026-127102
No data.
Status : Received
Published: 2026-11-13T15:17:44.177
Modified: 2026-11-13T15:17:44.177
Link: CVE-2026-127102
No data.
ReportizFlow