Metrics
Affected Vendors & Products
Mon, 01 Dec 2025 22:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
Mon, 01 Dec 2025 21:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | An issue was discovered in BMC Control-M 9.0.21.300. When Control-M Server has a database connection, it runs DBUStatus.exe frequently, which then calls dbu_connection_details.vbs with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. | BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs 'DBUStatus.exe' frequently, which then calls 'dbu_connection_details.vbs' with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307. |
| Title | BMC Control-M/Server cleartext database credentials in process lists and logs | |
| Weaknesses | CWE-214 | |
| Metrics |
cvssV4_0
|
Mon, 27 Oct 2025 16:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| CPEs | cpe:2.3:a:bmc:control-m:*:*:*:*:*:*:*:* | |
| Metrics |
cvssV3_1
|
cvssV3_1
|
Tue, 16 Sep 2025 19:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
cvssV3_1
|
cvssV3_1
|
Tue, 12 Aug 2025 15:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
Tue, 12 Aug 2025 14:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Weaknesses | CWE-532 | |
| Metrics |
cvssV3_1
|
Tue, 12 Aug 2025 08:00:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Bmc
Bmc control-m |
|
| Vendors & Products |
Bmc
Bmc control-m |
Thu, 07 Aug 2025 20:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | An issue was discovered in BMC Control-M 9.0.21.300. When Control-M Server has a database connection, it runs DBUStatus.exe frequently, which then calls dbu_connection_details.vbs with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. | |
| References |
|
Status: PUBLISHED
Assigner: mitre
Published: 2025-08-07T00:00:00.000Z
Updated: 2025-12-01T21:57:06.906Z
Reserved: 2025-05-23T00:00:00.000Z
Link: CVE-2025-48709
Updated: 2025-08-12T14:06:38.841Z
Status : Awaiting Analysis
Published: 2025-08-07T20:15:28.117
Modified: 2025-12-01T22:15:48.363
Link: CVE-2025-48709
No data.
ReportizFlow