Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-8232", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2024-08-27T13:40:41.730Z", "datePublished": "2024-09-10T19:44:18.096Z", "dateUpdated": "2024-09-12T13:36:10.295Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "SpiderControl SCADA Web Server", "vendor": "iniNet Solutions GmbH", "versions": [{"lessThanOrEqual": "v2.09", "status": "affected", "version": "0", "versionType": "custom"}]}], "credits": [{"lang": "en", "type": "finder", "value": "elcazators ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity, Inc reported this vulnerability to CERT/CC."}], "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "SpiderControl SCADA Web Server has a vulnerability that could allow an \nattacker to upload specially crafted malicious files without \nauthentication."}], "value": "SpiderControl SCADA Web Server has a vulnerability that could allow an \nattacker to upload specially crafted malicious files without \nauthentication."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}, {"cvssV4_0": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-434", "description": "CWE-434 Unrestricted Upload of File with Dangerous Type", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2024-09-10T19:44:18.096Z"}, "references": [{"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-254-02"}], "solutions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "IniNet Solutions has released a new version of SpiderControl SCADA \nServer, (3.2.2), to address this issue. It can be found at the following\n location: <a target=\"_blank\" rel=\"nofollow\" href=\"https://spidercontrol.net/download/download-area-2/?lang=en\">https://spidercontrol.net/download/download-area-2/?lang=en</a>\n\n<br>"}], "value": "IniNet Solutions has released a new version of SpiderControl SCADA \nServer, (3.2.2), to address this issue. It can be found at the following\n location: https://spidercontrol.net/download/download-area-2/?lang=en"}], "source": {"advisory": "ICSA-24-254-02", "discovery": "EXTERNAL"}, "title": "iniNet Solutions SpiderControl SCADA Web Server Unrestricted Upload of File with Dangerous Type", "workarounds": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "IniNet Solutions reminds users that the webserver is designed to be used\n in a protected environment. IniNet Solutions GmbH recommends that users\n never connect control system software directly to the Internet. If a \nuser must connect to the Internet, IniNet Solutions GmbH recommends \nusing a managed infrastructure to do so.\n\n<br>"}], "value": "IniNet Solutions reminds users that the webserver is designed to be used\n in a protected environment. IniNet Solutions GmbH recommends that users\n never connect control system software directly to the Internet. If a \nuser must connect to the Internet, IniNet Solutions GmbH recommends \nusing a managed infrastructure to do so."}], "x_generator": {"engine": "Vulnogram 0.2.0"}}, "adp": [{"affected": [{"vendor": "spidercontrol", "product": "scada_webserver", "cpes": ["cpe:2.3:a:spidercontrol:scada_webserver:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "0", "status": "affected", "lessThanOrEqual": "2.09", "versionType": "custom"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-09-12T13:34:02.939872Z", "id": "CVE-2024-8232", "options": [{"Exploitation": "none"}, {"Automatable": "yes"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-09-12T13:36:10.295Z"}}]}}