Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-8175", "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "state": "PUBLISHED", "assignerShortName": "CERTVDE", "dateReserved": "2024-08-26T09:58:34.794Z", "datePublished": "2024-09-25T08:04:23.196Z", "dateUpdated": "2024-09-25T14:02:28.368Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control for Linux ARM SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [{"lessThan": "3.5.20.30", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [{"lessThan": "3.5.20.30", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [{"lessThan": "3.5.20.30", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [{"lessThan": "3.5.20.30", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [{"lessThan": "3.5.20.30", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [{"lessThan": "3.5.20.30", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Runtime Toolkit", "vendor": "CODESYS", "versions": [{"lessThan": "3.5.20.30", "status": "affected", "version": "0", "versionType": "semver"}]}, {"defaultStatus": "unaffected", "product": "CODESYS Virtual Control SL", "vendor": "CODESYS", "versions": [{"lessThan": "4.14.0.0", "status": "affected", "version": "0", "versionType": "semver"}]}], "credits": [{"lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "ABB"}], "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS."}], "value": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-754", "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE", "dateUpdated": "2024-09-25T13:33:10.408Z"}, "references": [{"url": "https://cert.vde.com/en/advisories/VDE-2024-057"}, {"tags": ["vendor-advisory"], "url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=18604&token=d5e1e2820ee63077b875b3bb41014b1f102e88a3&download="}], "source": {"advisory": "VDE-2024-057", "defect": ["CERT@VDE#641681"], "discovery": "UNKNOWN"}, "title": "CODESYS: web server vulnerable to DoS", "x_generator": {"engine": "Vulnogram 0.1.0-dev"}}, "adp": [{"affected": [{"vendor": "codesys", "product": "runtime_toolkit", "cpes": ["cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "0", "status": "affected", "lessThan": "4.14.0.0", "versionType": "custom"}]}, {"vendor": "codesys", "product": "control_rte_\\(for_beckhoff_cx\\)_sl", "cpes": ["cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "0", "status": "affected", "lessThan": "3.5.20.30", "versionType": "custom"}]}, {"vendor": "codesys", "product": "virtual_control_sl", "cpes": ["cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "0", "status": "affected", "lessThan": "4.14.0.0", "versionType": "custom"}]}, {"vendor": "codesys", "product": "runtime_toolkit", "cpes": ["cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*", "cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "0", "status": "affected", "lessThan": "3.5.20.30", "versionType": "custom"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-09-25T13:44:03.391474Z", "id": "CVE-2024-8175", "options": [{"Exploitation": "none"}, {"Automatable": "yes"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-09-25T14:02:28.368Z"}}]}}