Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-7940", "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "state": "PUBLISHED", "assignerShortName": "Hitachi Energy", "dateReserved": "2024-08-19T14:56:24.826Z", "datePublished": "2024-08-27T12:52:24.601Z", "dateUpdated": "2024-08-27T13:43:15.252Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "MicroSCADA SYS600", "vendor": "Hitachi Energy", "versions": [{"lessThanOrEqual": "10.5", "status": "affected", "version": "10.2", "versionType": "custom"}]}], "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "The product exposes a service that is intended for local only to\nall network interfaces without any authentication."}], "value": "The product exposes a service that is intended for local only to\nall network interfaces without any authentication."}], "impacts": [{"capecId": "CAPEC-115", "descriptions": [{"lang": "en", "value": "CAPEC-115 Authentication Bypass"}]}], "metrics": [{"cvssV3_1": {"attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy", "dateUpdated": "2024-08-27T12:52:54.589Z"}, "references": [{"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160&LanguageCode=en&DocumentPartId=&Action=Launch"}], "source": {"discovery": "UNKNOWN"}, "x_generator": {"engine": "Vulnogram 0.2.0"}}, "adp": [{"affected": [{"vendor": "hitachienergy", "product": "microscada_x_sys600", "cpes": ["cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "10.2", "status": "affected", "lessThanOrEqual": "10.5", "versionType": "custom"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-08-27T13:26:16.109923Z", "id": "CVE-2024-7940", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-08-27T13:43:15.252Z"}}]}}