A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543)
History

Tue, 10 Dec 2024 14:00:00 +0000

Type Values Removed Values Added
Description A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543) A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543)
References

Mon, 18 Nov 2024 18:15:00 +0000

Type Values Removed Values Added
First Time appeared Siemens
Siemens tecnomatix Plant Simulation
CPEs cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*
Vendors & Products Siemens
Siemens tecnomatix Plant Simulation
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}


Mon, 18 Nov 2024 15:45:00 +0000

Type Values Removed Values Added
Description A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543)
Weaknesses CWE-125
References
Metrics cvssV3_1

{'score': 7.8, 'vector': 'CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H'}

cvssV4_0

{'score': 7.3, 'vector': 'CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}


cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published: 2024-11-18T15:39:38.552Z

Updated: 2024-12-10T13:54:10.791Z

Reserved: 2024-11-14T12:25:53.336Z

Link: CVE-2024-52574

cve-icon Vulnrichment

Updated: 2024-11-18T17:58:58.012Z

cve-icon NVD

Status : Modified

Published: 2024-11-18T16:15:29.400

Modified: 2024-12-10T14:30:46.367

Link: CVE-2024-52574

cve-icon Redhat

No data.