Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:5015-u8ihft_firmware:1.011:*:*:*:*:*:*:*", "matchCriteriaId": "6208DD6F-0700-486A-9623-9F2F621CE80D", "vulnerable": true}, {"criteria": "cpe:2.3:o:rockwellautomation:5015-u8ihft_firmware:1.012:*:*:*:*:*:*:*", "matchCriteriaId": "899897D4-5A3A-4A96-96D1-98283B2A4D42", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:5015-u8ihft:-:*:*:*:*:*:*:*", "matchCriteriaId": "ACBE88CB-97CA-4048-8A4D-5BBF4679C91A", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "CVE-2024-45825 IMPACT\nA denial-of-service vulnerability exists in the affected products. The vulnerability occurs when a malformed CIP packet is sent over the network to the device and results in a major nonrecoverable fault causing a denial-of-service."}, {"lang": "es", "value": "CVE-2024-45825 IMPACTO Existe una vulnerabilidad de denegaci\u00f3n de servicio en los productos afectados. La vulnerabilidad se produce cuando se env\u00eda un paquete CIP mal formado a trav\u00e9s de la red al dispositivo y da como resultado una falla grave no recuperable que causa una denegaci\u00f3n de servicio."}], "id": "CVE-2024-45825", "lastModified": "2024-10-02T14:43:08.720", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "PSIRT@rockwellautomation.com", "type": "Secondary"}], "cvssMetricV40": [{"cvssData": {"attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE"}, "source": "PSIRT@rockwellautomation.com", "type": "Secondary"}]}, "published": "2024-09-12T15:18:23.387", "references": [{"source": "PSIRT@rockwellautomation.com", "tags": ["Vendor Advisory"], "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1699.html"}], "sourceIdentifier": "PSIRT@rockwellautomation.com", "vulnStatus": "Analyzed", "weaknesses": [{"description": [{"lang": "en", "value": "NVD-CWE-noinfo"}], "source": "nvd@nist.gov", "type": "Primary"}, {"description": [{"lang": "en", "value": "CWE-20"}], "source": "PSIRT@rockwellautomation.com", "type": "Secondary"}]}