A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
History

Tue, 10 Dec 2024 14:00:00 +0000

Type Values Removed Values Added
Description A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process. A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
References

Tue, 08 Oct 2024 18:15:00 +0000

Type Values Removed Values Added
First Time appeared Siemens
Siemens tecnomatix Plant Simulation
CPEs cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*
Vendors & Products Siemens
Siemens tecnomatix Plant Simulation
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}


Tue, 08 Oct 2024 08:45:00 +0000

Type Values Removed Values Added
Description A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
Weaknesses CWE-787
References
Metrics cvssV3_1

{'score': 7.8, 'vector': 'CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H'}

cvssV4_0

{'score': 7.3, 'vector': 'CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}


cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published: 2024-10-08T08:40:31.722Z

Updated: 2024-12-10T13:53:42.763Z

Reserved: 2024-08-29T11:28:48.106Z

Link: CVE-2024-45471

cve-icon Vulnrichment

Updated: 2024-10-08T17:37:10.009Z

cve-icon NVD

Status : Modified

Published: 2024-10-08T09:15:14.293

Modified: 2024-12-10T14:30:43.137

Link: CVE-2024-45471

cve-icon Redhat

No data.