Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9BBCA76-7B4C-4CC5-A782-489CA4223C04", "versionEndIncluding": "2020", "vulnerable": true}, {"criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:*:*:*:*", "matchCriteriaId": "9F184512-5D11-47F4-8555-EA6FF93C106F", "vulnerable": true}, {"criteria": "cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*", "matchCriteriaId": "BF28259A-30A6-4BB1-B262-A006AB74AFFA", "vulnerable": true}, {"criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*", "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F", "vulnerable": true}, {"criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*", "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE", "vulnerable": true}, {"criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*", "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68", "vulnerable": true}, {"criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*", "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E", "vulnerable": true}, {"criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*", "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285", "vulnerable": true}, {"criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*", "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions."}, {"lang": "es", "value": " Un problema de corrupci\u00f3n de memoria debido a una verificaci\u00f3n de longitud incorrecta en LabVIEW tdcore.dll puede revelar informaci\u00f3n o resultar en la ejecuci\u00f3n de c\u00f3digo arbitrario. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."}], "id": "CVE-2024-4080", "lastModified": "2024-11-21T09:42:09.330", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "security@ni.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}], "cvssMetricV40": [{"cvssData": {"attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "ACTIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "HIGH"}, "source": "security@ni.com", "type": "Secondary"}]}, "published": "2024-07-23T14:15:14.590", "references": [{"source": "security@ni.com", "tags": ["Vendor Advisory"], "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html"}], "sourceIdentifier": "security@ni.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-119"}], "source": "security@ni.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-787"}], "source": "nvd@nist.gov", "type": "Primary"}]}