Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-37039", "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "state": "PUBLISHED", "assignerShortName": "schneider", "dateReserved": "2024-05-31T06:52:05.762Z", "datePublished": "2024-06-12T16:54:23.117Z", "dateUpdated": "2024-08-02T03:43:50.886Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "Sage 1410", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Versions C3414-500-S02K5_P8 and prior"}]}, {"defaultStatus": "unaffected", "product": "Sage 1430", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Versions C3414-500-S02K5_P8 and prior"}]}, {"defaultStatus": "unaffected", "product": "Sage 1450", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Versions C3414-500-S02K5_P8 and prior"}]}, {"defaultStatus": "unaffected", "product": "Sage 2400", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Versions C3414-500-S02K5_P8 and prior"}]}, {"defaultStatus": "unaffected", "product": "Sage 3030 Magnum", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Versions C3414-500-S02K5_P8 and prior"}]}, {"defaultStatus": "unaffected", "product": "Sage 4400", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Versions C3414-500-S02K5_P8 and prior"}]}], "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "\n\n\n\n\n\n\n\n\n\nCWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request.\n\n\n\n\n\n\n\n\n\n"}], "value": "CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request."}], "metrics": [{"cvssV3_1": {"attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-252", "description": "CWE-252 Unchecked Return Value", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider", "dateUpdated": "2024-06-12T16:54:23.117Z"}, "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf"}], "source": {"discovery": "UNKNOWN"}, "x_generator": {"engine": "Vulnogram 0.2.0"}}, "adp": [{"affected": [{"vendor": "schneider-electric", "product": "sage_4400", "cpes": ["cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*", "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*", "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*", "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*", "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*", "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "0", "status": "affected", "lessThanOrEqual": "c3414-500-s02k5_p8", "versionType": "custom"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-06-12T18:24:08.466465Z", "id": "CVE-2024-37039", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-06-12T18:33:50.964Z"}}, {"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T03:43:50.886Z"}, "title": "CVE Program Container", "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf", "tags": ["x_transferred"]}]}]}}