Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-31980", "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "state": "PUBLISHED", "assignerShortName": "siemens", "dateReserved": "2024-04-08T12:20:23.712Z", "datePublished": "2024-05-14T10:02:27.405Z", "dateUpdated": "2024-08-02T01:59:50.660Z"}, "containers": {"cna": {"providerMetadata": {"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2024-05-15T07:24:15.740Z"}, "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.256), Parasolid V36.0 (All versions < V36.0.210), Parasolid V36.1 (All versions < V36.1.185). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T part file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-23468)"}], "affected": [{"vendor": "Siemens", "product": "Parasolid V35.1", "versions": [{"status": "affected", "version": "0", "lessThan": "V35.1.256", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "Parasolid V36.0", "versions": [{"status": "affected", "version": "0", "lessThan": "V36.0.210", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "Parasolid V36.1", "versions": [{"status": "affected", "version": "0", "lessThan": "V36.1.185", "versionType": "custom"}], "defaultStatus": "unknown"}], "metrics": [{"cvssV3_1": {"version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH"}}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "type": "CWE"}]}], "references": [{"url": "https://cert-portal.siemens.com/productcert/html/ssa-489698.html"}]}, "adp": [{"affected": [{"vendor": "siemens", "product": "parasolid", "cpes": ["cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "35.1", "status": "affected", "lessThan": "35.1.256", "versionType": "custom"}]}, {"vendor": "siemens", "product": "parasolid", "cpes": ["cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "36.0", "status": "affected", "lessThan": "36.0.210", "versionType": "custom"}]}, {"vendor": "siemens", "product": "parasolid", "cpes": ["cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "36.1", "status": "affected", "lessThan": "36.1.185", "versionType": "custom"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-05-14T13:39:14.173926Z", "id": "CVE-2024-31980", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-06-06T17:09:32.754Z"}}, {"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T01:59:50.660Z"}, "title": "CVE Program Container", "references": [{"url": "https://cert-portal.siemens.com/productcert/html/ssa-489698.html", "tags": ["x_transferred"]}]}]}}