Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-29177", "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "state": "PUBLISHED", "assignerShortName": "dell", "dateReserved": "2024-03-18T08:44:18.924Z", "datePublished": "2024-06-26T02:46:55.073Z", "dateUpdated": "2024-08-02T01:10:54.086Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "PowerProtect DD", "vendor": "Dell", "versions": [{"lessThanOrEqual": "7.13", "status": "affected", "version": "7.0", "versionType": "semver"}, {"lessThan": "2.7.7", "status": "affected", "version": "N/A", "versionType": "semver"}, {"lessThan": "5.16.0.0", "status": "affected", "version": "N/A", "versionType": "semver"}, {"lessThanOrEqual": "7.13", "status": "affected", "version": "7.8", "versionType": "semver"}]}], "datePublic": "2024-06-24T06:30:00.000Z", "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."}], "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-532", "description": "CWE-532: Insertion of Sensitive Information into Log File", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell", "dateUpdated": "2024-06-26T02:46:55.073Z"}, "references": [{"tags": ["vendor-advisory"], "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"}], "source": {"discovery": "UNKNOWN"}, "x_generator": {"engine": "Vulnogram 0.2.0"}}, "adp": [{"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-06-26T19:05:17.020326Z", "id": "CVE-2024-29177", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-06-26T19:05:23.225Z"}}, {"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T01:10:54.086Z"}, "title": "CVE Program Container", "references": [{"tags": ["vendor-advisory", "x_transferred"], "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"}]}]}}