Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-2856", "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "state": "PUBLISHED", "assignerShortName": "VulDB", "dateReserved": "2024-03-23T05:47:39.796Z", "datePublished": "2024-03-24T06:31:04.241Z", "dateUpdated": "2024-08-21T15:03:56.980Z"}, "containers": {"cna": {"providerMetadata": {"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB", "dateUpdated": "2024-03-25T12:14:28.193Z"}, "title": "Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow", "problemTypes": [{"descriptions": [{"type": "CWE", "cweId": "CWE-121", "lang": "en", "description": "CWE-121 Stack-based Buffer Overflow"}]}], "affected": [{"vendor": "Tenda", "product": "AC10", "versions": [{"version": "16.03.10.13", "status": "affected"}, {"version": "16.03.10.20", "status": "affected"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."}, {"lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC10 16.03.10.13/16.03.10.20 entdeckt. Davon betroffen ist die Funktion fromSetSysTime der Datei /goform/SetSysTimeCfg. Mittels Manipulieren des Arguments timeZone mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."}], "metrics": [{"cvssV3_1": {"version": "3.1", "baseScore": 8.8, "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseSeverity": "HIGH"}}, {"cvssV3_0": {"version": "3.0", "baseScore": 8.8, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseSeverity": "HIGH"}}, {"cvssV2_0": {"version": "2.0", "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C"}}], "timeline": [{"time": "2024-03-23T00:00:00.000Z", "lang": "en", "value": "Advisory disclosed"}, {"time": "2024-03-23T01:00:00.000Z", "lang": "en", "value": "VulDB entry created"}, {"time": "2024-03-23T06:52:42.000Z", "lang": "en", "value": "VulDB entry last update"}], "credits": [{"lang": "en", "value": "wxhwxhwxh_miemie (VulDB User)", "type": "reporter"}], "references": [{"url": "https://vuldb.com/?id.257780", "name": "VDB-257780 | Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow", "tags": ["vdb-entry", "technical-description"]}, {"url": "https://vuldb.com/?ctiid.257780", "name": "VDB-257780 | CTI Indicators (IOB, IOC, IOA)", "tags": ["signature", "permissions-required"]}, {"url": "https://vuldb.com/?submit.299741", "name": "Submit #299741 | Tenda AC10 AC10 v4.0 V16.03.10.13\u3001V16.03.10.20 buffer overflow", "tags": ["third-party-advisory"]}, {"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetSysTime.md", "tags": ["exploit"]}]}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-01T19:25:42.134Z"}, "title": "CVE Program Container", "references": [{"url": "https://vuldb.com/?id.257780", "name": "VDB-257780 | Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow", "tags": ["vdb-entry", "technical-description", "x_transferred"]}, {"url": "https://vuldb.com/?ctiid.257780", "name": "VDB-257780 | CTI Indicators (IOB, IOC, IOA)", "tags": ["signature", "permissions-required", "x_transferred"]}, {"url": "https://vuldb.com/?submit.299741", "name": "Submit #299741 | Tenda AC10 AC10 v4.0 V16.03.10.13\u3001V16.03.10.20 buffer overflow", "tags": ["third-party-advisory", "x_transferred"]}, {"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetSysTime.md", "tags": ["exploit", "x_transferred"]}]}, {"affected": [{"vendor": "tenda", "product": "ac10_firmware", "cpes": ["cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "16.03.10.13", "status": "affected"}]}, {"vendor": "tenda", "product": "ac10_firmware", "cpes": ["cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "16.03.10.20", "status": "affected"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-08-21T15:00:54.641317Z", "id": "CVE-2024-2856", "options": [{"Exploitation": "poc"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-08-21T15:03:56.980Z"}}]}}