Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-2705", "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "state": "PUBLISHED", "assignerShortName": "VulDB", "dateReserved": "2024-03-20T09:49:55.324Z", "datePublished": "2024-03-20T16:31:04.186Z", "dateUpdated": "2024-08-01T19:18:48.341Z"}, "containers": {"cna": {"providerMetadata": {"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB", "dateUpdated": "2024-03-20T16:31:04.186Z"}, "title": "Tenda AC10U SetNetControlList formSetQosBand stack-based overflow", "problemTypes": [{"descriptions": [{"type": "CWE", "cweId": "CWE-121", "lang": "en", "description": "CWE-121 Stack-based Buffer Overflow"}]}], "affected": [{"vendor": "Tenda", "product": "AC10U", "versions": [{"version": "1.0", "status": "affected"}, {"version": "15.03.06.49", "status": "affected"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."}, {"lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC10U 1.0/15.03.06.49 entdeckt. Es geht hierbei um die Funktion formSetQosBand der Datei /goform/SetNetControlList. Dank Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."}], "metrics": [{"cvssV3_1": {"version": "3.1", "baseScore": 8.8, "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseSeverity": "HIGH"}}, {"cvssV3_0": {"version": "3.0", "baseScore": 8.8, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseSeverity": "HIGH"}}, {"cvssV2_0": {"version": "2.0", "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C"}}], "timeline": [{"time": "2024-03-20T00:00:00.000Z", "lang": "en", "value": "Advisory disclosed"}, {"time": "2024-03-20T01:00:00.000Z", "lang": "en", "value": "VulDB entry created"}, {"time": "2024-03-20T10:54:58.000Z", "lang": "en", "value": "VulDB entry last update"}], "credits": [{"lang": "en", "value": "yhryhryhr_mie (VulDB User)", "type": "reporter"}], "references": [{"url": "https://vuldb.com/?id.257456", "name": "VDB-257456 | Tenda AC10U SetNetControlList formSetQosBand stack-based overflow", "tags": ["vdb-entry", "technical-description"]}, {"url": "https://vuldb.com/?ctiid.257456", "name": "VDB-257456 | CTI Indicators (IOB, IOC, IOA)", "tags": ["signature", "permissions-required"]}, {"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetQosBand.md", "tags": ["exploit"]}]}, "adp": [{"affected": [{"vendor": "tenda", "product": "ac10u", "cpes": ["cpe:2.3:h:tenda:ac10u:1.0:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "1.0", "status": "affected"}]}, {"vendor": "tenda", "product": "ac10u_firmware", "cpes": ["cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "15.03.06.49", "status": "affected"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-03-20T20:07:24.389193Z", "id": "CVE-2024-2705", "options": [{"Exploitation": "poc"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-06-18T20:06:01.280Z"}}, {"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-01T19:18:48.341Z"}, "title": "CVE Program Container", "references": [{"url": "https://vuldb.com/?id.257456", "name": "VDB-257456 | Tenda AC10U SetNetControlList formSetQosBand stack-based overflow", "tags": ["vdb-entry", "technical-description", "x_transferred"]}, {"url": "https://vuldb.com/?ctiid.257456", "name": "VDB-257456 | CTI Indicators (IOB, IOC, IOA)", "tags": ["signature", "permissions-required", "x_transferred"]}, {"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetQosBand.md", "tags": ["exploit", "x_transferred"]}]}]}}