A vulnerability classified as critical has been found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This affects an unknown part of the file /admin/network/diag_traceroute6. The manipulation of the argument diag_traceroute6 leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
History

Tue, 10 Dec 2024 23:30:00 +0000

Type Values Removed Values Added
First Time appeared Engeniustech
Engeniustech eens500-ac
Engeniustech enh1350ext
Engeniustech enh1350ext Firmware
Engeniustech ens500-ac Firmware
Engeniustech ens620ext
Engeniustech ens620ext Firmware
CPEs cpe:2.3:h:engeniustech:eens500-ac:-:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:enh1350ext:-:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:ens620ext:-:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:enh1350ext_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:ens500-ac_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:ens620ext_firmware:*:*:*:*:*:*:*:*
Vendors & Products Engeniustech
Engeniustech eens500-ac
Engeniustech enh1350ext
Engeniustech enh1350ext Firmware
Engeniustech ens500-ac Firmware
Engeniustech ens620ext
Engeniustech ens620ext Firmware

Tue, 26 Nov 2024 16:15:00 +0000

Type Values Removed Values Added
First Time appeared Engenius
Engenius enh1350ext
Engenius ens500-ac
Engenius ens620ext
CPEs cpe:2.3:a:engenius:enh1350ext:20241118:*:*:*:*:*:*:*
cpe:2.3:a:engenius:ens500-ac:20241118:*:*:*:*:*:*:*
cpe:2.3:a:engenius:ens620ext:20241118:*:*:*:*:*:*:*
Vendors & Products Engenius
Engenius enh1350ext
Engenius ens500-ac
Engenius ens620ext
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'poc', 'Technical Impact': 'partial'}, 'version': '2.0.3'}


Mon, 25 Nov 2024 04:15:00 +0000

Type Values Removed Values Added
Title EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_traceroute6 command injection
Metrics cvssV4_0

{'score': 5.1, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X'}

cvssV3_0

{'score': 4.7, 'vector': 'CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L'}

cvssV4_0

{'score': 5.1, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N'}


Mon, 25 Nov 2024 05:15:00 +0000

Type Values Removed Values Added
Description A vulnerability classified as critical has been found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This affects an unknown part of the file /admin/network/diag_traceroute6. The manipulation of the argument diag_traceroute6 leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Weaknesses CWE-74
CWE-77
References
Metrics cvssV2_0

{'score': 5.8, 'vector': 'AV:N/AC:L/Au:M/C:P/I:P/A:P'}

cvssV3_1

{'score': 4.7, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L'}

cvssV4_0

{'score': 5.1, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X'}


cve-icon MITRE

Status: PUBLISHED

Assigner: VulDB

Published: 2024-11-25T04:00:27.286Z

Updated: 2024-11-26T15:48:44.903Z

Reserved: 2024-11-24T15:13:57.614Z

Link: CVE-2024-11654

cve-icon Vulnrichment

Updated: 2024-11-26T15:48:39.398Z

cve-icon NVD

Status : Analyzed

Published: 2024-11-25T04:15:05.577

Modified: 2024-12-10T23:13:58.150

Link: CVE-2024-11654

cve-icon Redhat

No data.