Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-0220", "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "state": "PUBLISHED", "assignerShortName": "ABB", "dateReserved": "2024-01-03T15:46:41.224Z", "datePublished": "2024-02-22T10:15:44.750Z", "dateUpdated": "2024-09-19T17:24:51.723Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "modules": ["Upgrade Service"], "product": "Automation Studio", "vendor": "B&R Industrial Automation", "versions": [{"lessThan": "4.6", "status": "affected", "version": "4.0", "versionType": "patch"}]}, {"defaultStatus": "unaffected", "product": "Technology Guarding", "vendor": "B&R Industrial Automation", "versions": [{"lessThan": "1.4.0", "status": "affected", "version": "1.0.0", "versionType": "patch"}]}], "datePublic": "2024-02-22T10:10:00.000Z", "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.\n\n<br>"}], "value": "B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data."}], "metrics": [{"cvssV3_1": {"attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-1240", "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation", "lang": "en", "type": "CWE"}]}, {"descriptions": [{"cweId": "CWE-319", "description": "CWE-319 Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE"}]}, {"descriptions": [{"cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code ('Code Injection')", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB", "dateUpdated": "2024-09-19T17:24:51.723Z"}, "references": [{"url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf"}], "source": {"advisory": "2023-P019", "discovery": "INTERNAL"}, "title": "B&R products use insufficient communication encryption", "x_generator": {"engine": "Vulnogram 0.1.0-dev"}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-01T17:41:15.976Z"}, "title": "CVE Program Container", "references": [{"url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf", "tags": ["x_transferred"]}]}, {"affected": [{"vendor": "br-automation", "product": "automation_studio", "cpes": ["cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "4.0", "status": "affected", "lessThan": "4.6", "versionType": "custom"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-02-22T16:23:26.378691Z", "id": "CVE-2024-0220", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-08-28T16:52:09.908Z"}}]}}