Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2023-5068", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2023-09-19T16:03:45.129Z", "datePublished": "2023-09-21T22:01:07.522Z", "dateUpdated": "2025-01-16T21:29:52.168Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "DIAScreen", "vendor": "Delta Electronics", "versions": [{"lessThan": "v1.3.2", "status": "affected", "version": "0", "versionType": "custom"}]}], "credits": [{"lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "kimiya working with Trend Micro Zero Day Initiative reported this vulnerability to CISA."}], "datePublic": "2023-09-21T21:59:00.000Z", "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "\nDelta Electronics DIAScreen may write past the end of an allocated \nbuffer while parsing a specially crafted input file. This could allow an\n attacker to execute code in the context of the current process.\n\n"}], "value": "Delta Electronics DIAScreen may write past the end of an allocated \nbuffer while parsing a specially crafted input file. This could allow an\n attacker to execute code in the context of the current process.\n\n"}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2023-09-21T22:01:07.522Z"}, "references": [{"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-264-03"}, {"url": "https://diastudio.deltaww.com/home/downloads?sec=download#catalog"}], "solutions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "\nDelta Electronics has released a new version (v1.3.2) of DIAScreen to address this issue.<br>\nUsers can download it at the <a target=\"_blank\" rel=\"nofollow\" href=\"https://diastudio.deltaww.com/home/downloads?sec=download#catalog\">download center of DIAStudio.</a> (Login required)\n\n<br>"}], "value": "Delta Electronics has released a new version (v1.3.2) of DIAScreen to address this issue.\n\nUsers can download it at the download center of DIAStudio. https://diastudio.deltaww.com/home/downloads \u00a0(Login required)\n\n\n"}], "source": {"discovery": "EXTERNAL"}, "title": "Delta Electronics DIAScreen Out-of-bounds Write", "x_generator": {"engine": "Vulnogram 0.1.0-dev"}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T07:44:53.703Z"}, "title": "CVE Program Container", "references": [{"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-264-03", "tags": ["x_transferred"]}, {"url": "https://diastudio.deltaww.com/home/downloads?sec=download#catalog", "tags": ["x_transferred"]}]}, {"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2025-01-16T21:20:21.648997Z", "id": "CVE-2023-5068", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-01-16T21:29:52.168Z"}}]}}