Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2023-4414", "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "state": "PUBLISHED", "assignerShortName": "VulDB", "dateReserved": "2023-08-18T08:15:50.848Z", "datePublished": "2023-08-18T16:00:05.398Z", "dateUpdated": "2024-11-21T14:58:33.583Z"}, "containers": {"cna": {"providerMetadata": {"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB", "dateUpdated": "2024-04-09T08:34:40.086Z"}, "title": "Byzoro Smart S85F Management Platform decodmail.php command injection", "problemTypes": [{"descriptions": [{"type": "CWE", "cweId": "CWE-77", "lang": "en", "description": "CWE-77 Command Injection"}]}], "affected": [{"vendor": "Byzoro", "product": "Smart S85F Management Platform", "versions": [{"version": "20230807", "status": "affected"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230807. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-237517 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."}, {"lang": "de", "value": "In Byzoro Smart S85F Management Platform bis 20230807 wurde eine kritische Schwachstelle ausgemacht. Betroffen ist eine unbekannte Verarbeitung der Datei /log/decodmail.php. Mittels dem Manipulieren des Arguments file mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."}], "metrics": [{"cvssV3_1": {"version": "3.1", "baseScore": 6.3, "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "baseSeverity": "MEDIUM"}}, {"cvssV3_0": {"version": "3.0", "baseScore": 6.3, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "baseSeverity": "MEDIUM"}}, {"cvssV2_0": {"version": "2.0", "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P"}}], "timeline": [{"time": "2023-08-18T00:00:00.000Z", "lang": "en", "value": "Advisory disclosed"}, {"time": "2023-08-18T00:00:00.000Z", "lang": "en", "value": "CVE reserved"}, {"time": "2023-08-18T02:00:00.000Z", "lang": "en", "value": "VulDB entry created"}, {"time": "2024-04-09T09:06:24.000Z", "lang": "en", "value": "VulDB entry last update"}], "credits": [{"lang": "en", "value": "RCEraser (VulDB User)", "type": "reporter"}], "references": [{"url": "https://vuldb.com/?id.237517", "name": "VDB-237517 | Byzoro Smart S85F Management Platform decodmail.php command injection", "tags": ["vdb-entry", "technical-description"]}, {"url": "https://vuldb.com/?ctiid.237517", "name": "VDB-237517 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": ["signature", "permissions-required"]}, {"url": "https://vuldb.com/?submit.191743", "name": "Submit #191743 | The Smart S85F management platform has an rce vulnerability", "tags": ["third-party-advisory"]}, {"url": "https://github.com/RCEraser/cve/blob/main/S85F.md", "tags": ["exploit"]}]}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T07:24:04.627Z"}, "title": "CVE Program Container", "references": [{"url": "https://vuldb.com/?id.237517", "name": "VDB-237517 | Byzoro Smart S85F Management Platform decodmail.php command injection", "tags": ["vdb-entry", "technical-description", "x_transferred"]}, {"url": "https://vuldb.com/?ctiid.237517", "name": "VDB-237517 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": ["signature", "permissions-required", "x_transferred"]}, {"url": "https://vuldb.com/?submit.191743", "name": "Submit #191743 | The Smart S85F management platform has an rce vulnerability", "tags": ["third-party-advisory", "x_transferred"]}, {"url": "https://github.com/RCEraser/cve/blob/main/S85F.md", "tags": ["exploit", "x_transferred"]}]}, {"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-11-21T14:57:34.036095Z", "id": "CVE-2023-4414", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-11-21T14:58:33.583Z"}}]}}