Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2023-31159", "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699", "state": "PUBLISHED", "assignerShortName": "SEL", "dateReserved": "2023-04-24T23:19:33.136Z", "datePublished": "2023-05-10T19:23:29.182Z", "dateUpdated": "2025-01-24T19:10:07.456Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "modules": ["Web management interface"], "platforms": ["Linux"], "product": "SEL-3505", "vendor": "Schweitzer Engineering Laboratories", "versions": [{"lessThan": "R150-V2", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R149-V4", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R148-V7", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R147-V6", "status": "affected", "version": "R132-V0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "modules": ["Web management interface"], "platforms": ["Linux"], "product": "SEL-3505-3", "vendor": "Schweitzer Engineering Laboratories", "versions": [{"lessThan": "R150-V2", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R149-V4", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R148-V7", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R147-V6", "status": "affected", "version": "R132-V0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "modules": ["Web management interface"], "platforms": ["Linux"], "product": "SEL-3530", "vendor": "Schweitzer Engineering Laboratories", "versions": [{"lessThan": "R150-V2", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R149-V4", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R148-V7", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R147-V6", "status": "affected", "version": "R132-V0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "modules": ["Web management interface"], "platforms": ["Linux"], "product": "SEL-3530-4", "vendor": "Schweitzer Engineering Laboratories", "versions": [{"lessThan": "R150-V2", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R149-V4", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R148-V7", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R147-V6", "status": "affected", "version": "R132-V0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "modules": ["Web management interface"], "platforms": ["Linux"], "product": "SEL-3532", "vendor": "Schweitzer Engineering Laboratories", "versions": [{"lessThan": "R150-V2", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R149-V4", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R148-V7", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R147-V6", "status": "affected", "version": "R132-V0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "modules": ["Web management interface"], "platforms": ["Linux"], "product": "SEL-3555", "vendor": "Schweitzer Engineering Laboratories", "versions": [{"lessThan": "R150-V2", "status": "affected", "version": "R134-V0", "versionType": "custom"}, {"lessThan": "R149-V4", "status": "affected", "version": "R134-V0", "versionType": "custom"}, {"lessThan": "R148-V7", "status": "affected", "version": "R134-V0", "versionType": "custom"}, {"lessThan": "R147-V6", "status": "affected", "version": "R134-V0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "modules": ["Web management interface"], "platforms": ["Linux"], "product": "SEL-3560S", "vendor": "Schweitzer Engineering Laboratories", "versions": [{"lessThan": "R150-V2", "status": "affected", "version": "R144-V2", "versionType": "custom"}, {"lessThan": "R149-V4", "status": "affected", "version": "R144-V2", "versionType": "custom"}, {"lessThan": "R148-V7", "status": "affected", "version": "R144-V2", "versionType": "custom"}, {"lessThan": "R147-V6", "status": "affected", "version": "R144-V2", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "modules": ["Web management interface"], "platforms": ["Linux"], "product": "SEL-3560E", "vendor": "Schweitzer Engineering Laboratories", "versions": [{"lessThan": "R150-V2", "status": "affected", "version": "R144-V2", "versionType": "custom"}, {"lessThan": "R149-V4", "status": "affected", "version": "R144-V2", "versionType": "custom"}, {"lessThan": "R148-V7", "status": "affected", "version": "R144-V2", "versionType": "custom"}, {"lessThan": "R147-V6", "status": "affected", "version": "R144-V2", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "modules": ["Web management interface"], "platforms": ["Linux"], "product": "SEL-2241 RTAC module", "vendor": "Schweitzer Engineering Laboratories", "versions": [{"lessThan": "R150-V2", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R149-V4", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R148-V7", "status": "affected", "version": "R132-V0", "versionType": "custom"}, {"lessThan": "R147-V6", "status": "affected", "version": "R132-V0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "modules": ["Web management interface"], "platforms": ["Linux"], "product": "SEL-3350", "vendor": "Schweitzer Engineering Laboratories", "versions": [{"lessThan": "R150-V2", "status": "affected", "version": "R148-V0", "versionType": "custom"}, {"lessThan": "R149-V4", "status": "affected", "version": "R148-V0", "versionType": "custom"}, {"lessThan": "R148-V7", "status": "affected", "version": "R148-V0", "versionType": "custom"}]}], "credits": [{"lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Andrea Palanca, Nozomi Networks"}], "datePublic": "2023-05-10T07:00:00.000Z", "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "\n\n<div><div>An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.</div></div>\n\n<p>See SEL Service Bulletin dated 2022-11-15 for more details.<br></p>"}], "value": "\nAn Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"}], "impacts": [{"capecId": "CAPEC-242", "descriptions": [{"lang": "en", "value": "CAPEC-242 Code Injection"}]}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-79", "description": "CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "5804bb70-792c-43e0-8596-486cc0efe699", "shortName": "SEL", "dateUpdated": "2023-05-10T19:23:29.182Z"}, "references": [{"url": "https://selinc.com/support/security-notifications/external-reports/"}, {"url": "https://www.nozominetworks.com/blog/"}], "source": {"discovery": "EXTERNAL"}, "title": "Improper Neutralization of Input During Web Page Generation", "x_generator": {"engine": "Vulnogram 0.1.0-dev"}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T14:45:25.784Z"}, "title": "CVE Program Container", "references": [{"url": "https://selinc.com/support/security-notifications/external-reports/", "tags": ["x_transferred"]}, {"url": "https://www.nozominetworks.com/blog/", "tags": ["x_transferred"]}]}, {"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2025-01-24T19:10:03.615553Z", "id": "CVE-2023-31159", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-01-24T19:10:07.456Z"}}]}}