Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2023-28003", "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "state": "PUBLISHED", "assignerShortName": "schneider", "dateReserved": "2023-03-09T15:40:32.544Z", "datePublished": "2023-04-18T20:43:50.362Z", "dateUpdated": "2025-02-05T21:23:55.818Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "EcoStruxure Power Monitoring Expert", "vendor": "Schneider Electric", "versions": [{"lessThanOrEqual": "PME 2022", "status": "affected", "version": "All ", "versionType": "custom"}]}], "datePublic": "2023-03-14T07:00:00.000Z", "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "\n\n\n\nA CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to\nmaintain unauthorized access over a hijacked session in PME after the legitimate user has\nsigned out of their account.\n\n\n\n"}], "value": "\n\n\nA CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to\nmaintain unauthorized access over a hijacked session in PME after the legitimate user has\nsigned out of their account.\n\n\n\n"}], "metrics": [{"cvssV3_1": {"attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-613", "description": "CWE-613 Insufficient Session Expiration", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider", "dateUpdated": "2023-04-18T20:43:50.362Z"}, "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-01.pdf"}], "source": {"discovery": "UNKNOWN"}, "x_generator": {"engine": "Vulnogram 0.1.0-dev"}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T12:23:30.805Z"}, "title": "CVE Program Container", "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-01.pdf", "tags": ["x_transferred"]}]}, {"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2025-02-05T21:23:43.454658Z", "id": "CVE-2023-28003", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-02-05T21:23:55.818Z"}}]}}