Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2023-27975", "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "state": "PUBLISHED", "assignerShortName": "schneider", "dateReserved": "2023-03-09T05:25:56.973Z", "datePublished": "2024-02-14T16:55:41.495Z", "dateUpdated": "2024-08-02T12:23:30.803Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "EcoStruxure Control Expert", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Versions prior to v16.0"}]}, {"defaultStatus": "unaffected", "product": "EcoStruxure Process Expert", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Versions prior to v2023"}]}], "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "\n\nCWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized\naccess to the project file in EcoStruxure Control Expert when a local user tampers with the\nmemory of the engineering workstation.\n\n"}], "value": "\nCWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized\naccess to the project file in EcoStruxure Control Expert when a local user tampers with the\nmemory of the engineering workstation.\n\n"}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-522", "description": "CWE-522 Insufficiently Protected Credentials", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider", "dateUpdated": "2024-02-14T16:55:41.495Z"}, "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-01.pdf"}], "source": {"discovery": "UNKNOWN"}, "x_generator": {"engine": "Vulnogram 0.1.0-dev"}}, "adp": [{"title": "CISA ADP Vulnrichment", "metrics": [{"other": {"type": "ssvc", "content": {"id": "CVE-2023-27975", "role": "CISA Coordinator", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "partial"}], "version": "2.0.3", "timestamp": "2024-02-21T20:31:05.372971Z"}}}], "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-06-04T17:24:48.765Z"}}, {"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T12:23:30.803Z"}, "title": "CVE Program Container", "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-01.pdf", "tags": ["x_transferred"]}]}]}}