Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2023-0102", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2023-01-06T18:50:02.310Z", "datePublished": "2023-02-15T17:20:48.504Z", "dateUpdated": "2025-01-16T21:57:08.084Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "modules": ["Operating System"], "product": "XBC-DN32U", "vendor": "LS Electric", "versions": [{"status": "affected", "version": "01.80"}]}], "credits": [{"lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "HeeA Go of Dankook University reported these vulnerabilities."}], "datePublic": "2023-02-09T20:58:00.000Z", "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "<p>LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files.</p>"}], "value": "LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files.\n\n"}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2023-02-15T17:20:48.504Z"}, "references": [{"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02"}], "source": {"discovery": "EXTERNAL"}, "title": "CVE-2023-0102", "workarounds": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "\n\n<p>LS ELECTRIC is developing mitigations (to be released tentatively by the end of 2023) and recommends users follow the provided workarounds to reduce the risk of exploitation: </p><ul><li>Restrict communication to the PLC to only trusted IP addresses and trusted devices by enabling the \u201cHost Table\u201d option in the configuration window of the PLC.</li></ul>"}], "value": "\nLS ELECTRIC is developing mitigations (to be released tentatively by the end of 2023) and recommends users follow the provided workarounds to reduce the risk of exploitation: \n\n * Restrict communication to the PLC to only trusted IP addresses and trusted devices by enabling the \u201cHost Table\u201d option in the configuration window of the PLC.\n\n\n"}], "x_generator": {"engine": "VINCE 2.0.6", "env": "prod", "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-0102"}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T05:02:43.495Z"}, "title": "CVE Program Container", "references": [{"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02", "tags": ["x_transferred"]}]}, {"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2025-01-16T20:56:55.423074Z", "id": "CVE-2023-0102", "options": [{"Exploitation": "none"}, {"Automatable": "yes"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-01-16T21:57:08.084Z"}}]}}