Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2022-4634", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2022-12-21T19:00:45.471Z", "datePublished": "2023-02-02T22:53:40.907Z", "dateUpdated": "2025-01-16T21:58:12.760Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "ScreenEditor", "vendor": "Delta Industrial Automation", "versions": [{"lessThanOrEqual": "1.01.5", "status": "affected", "version": "all versions", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "CNCSoft", "vendor": "Delta Industrial Automation", "versions": [{"lessThan": "v1.01.34", "status": "affected", "version": "all versions", "versionType": "custom"}]}], "credits": [{"lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Simon Humbert, working with Trend Micro Zero Day Initiative"}], "datePublic": "2023-01-26T15:14:00.000Z", "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "<p>All versions prior to Delta Electronic\u2019s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code.</p>"}], "value": "All versions prior to Delta Electronic\u2019s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code.\n\n"}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-121", "description": "CWE-121", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2023-02-02T22:53:40.907Z"}, "references": [{"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-026-01"}], "solutions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">Delta Electronics released an updated version of CNCSoft and recommends users update to </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1&q=cncsoft&sort_expr=cdate&sort_dir=DESC\">v1.01.34 or later</a><span style=\"background-color: rgb(255, 255, 255);\">. </span>\n\n<br>"}], "value": "\nDelta Electronics released an updated version of CNCSoft and recommends users update to v1.01.34 or later https://downloadcenter.deltaww.com/en-US/DownloadCenter . \n\n\n"}], "source": {"discovery": "EXTERNAL"}, "title": "CVE-2022-4634", "x_generator": {"engine": "VINCE 2.0.6", "env": "prod", "origin": "https://cveawg.mitre.org/api/cve/CVE-2022-4634"}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T01:48:39.487Z"}, "title": "CVE Program Container", "references": [{"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-026-01", "tags": ["x_transferred"]}]}, {"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2025-01-16T20:32:07.343464Z", "id": "CVE-2022-4634", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-01-16T21:58:12.760Z"}}]}}