Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*", "matchCriteriaId": "C89891C1-DFD7-4E1F-80A9-7485D86A15B5", "versionEndExcluding": "1.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*", "matchCriteriaId": "4664B195-AF14-4834-82B3-0B2C98020EB6", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "75BC588E-CDF0-404E-AD61-02093A1DF343", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "A334F7B4-7283-4453-BAED-D2E01B7F8A6E", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEC INS (Todas las versiones "}], "id": "CVE-2022-45093", "lastModified": "2024-11-21T07:28:46.053", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 6.0, "source": "productcert@siemens.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2023-01-10T12:15:23.523", "references": [{"source": "productcert@siemens.com", "tags": ["Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-22"}], "source": "productcert@siemens.com", "type": "Secondary"}]}