Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:totolink:lr350_firmware:9.3.5u.6369_b20220309:*:*:*:*:*:*:*", "matchCriteriaId": "6E7C618F-D415-4075-96A5-45E44B52FB62", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:totolink:lr350:-:*:*:*:*:*:*:*", "matchCriteriaId": "4CA0663B-3F55-44EF-AF32-F83AB0411748", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 contains a command injection via the ussd parameter in the setUssd function."}, {"lang": "es", "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 contiene una inyecci\u00f3n de comando a trav\u00e9s del par\u00e1metro ussd en la funci\u00f3n setUssd."}], "id": "CVE-2022-44251", "lastModified": "2025-04-25T21:15:35.030", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary"}]}, "published": "2022-11-23T16:15:10.577", "references": [{"source": "cve@mitre.org", "tags": ["Exploit", "Third Party Advisory"], "url": "https://brief-nymphea-813.notion.site/LR350-command-injection-setUssd-f25d6489a0e44468bf455e7af1173fdb"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Exploit", "Third Party Advisory"], "url": "https://brief-nymphea-813.notion.site/LR350-command-injection-setUssd-f25d6489a0e44468bf455e7af1173fdb"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-78"}], "source": "nvd@nist.gov", "type": "Primary"}, {"description": [{"lang": "en", "value": "CWE-78"}], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary"}]}