Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:robustel:r1510_firmware:3.1.16:*:*:*:*:*:*:*", "matchCriteriaId": "600CA085-D833-4551-B4AC-81D4EEA2F719", "vulnerable": true}, {"criteria": "cpe:2.3:o:robustel:r1510_firmware:3.3.0:*:*:*:*:*:*:*", "matchCriteriaId": "6F5663AF-C644-4A6A-A446-6B2F6E865528", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:robustel:r1510:-:*:*:*:*:*:*:*", "matchCriteriaId": "70006835-1E28-4F2C-B84D-C1B8B3C9EB93", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "A denial of service vulnerability exists in the web_server hashFirst functionality of Robustel R1510 3.1.16 and 3.3.0. A specially-crafted network request can lead to denial of service. An attacker can send a sequence of requests to trigger this vulnerability.This denial of service is in the `/action/import_nodejs_app/` API."}, {"lang": "es", "value": "Se presenta una vulnerabilidad de denegaci\u00f3n de servicio en la funcionalidad hashFirst del servidor web de Robustel R1510 versiones 3.1.16 y 3.3.0. Una petici\u00f3n de red especialmente dise\u00f1ada puede conllevar a una denegaci\u00f3n de servicio. Un atacante puede enviar una secuencia de peticiones para desencadenar esta vulnerabilidad. La API \"/action/import_nodejs_app/\" est\u00e1 afectada por la vulnerabilidad de inyecci\u00f3n de comandos"}], "id": "CVE-2022-35265", "lastModified": "2024-11-21T07:11:00.217", "metrics": {"cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0"}, "exploitabilityScore": 1.2, "impactScore": 3.6, "source": "talos-cna@cisco.com", "type": "Secondary"}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2022-10-25T17:15:54.063", "references": [{"source": "talos-cna@cisco.com", "tags": ["Exploit", "Third Party Advisory"], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1575"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Exploit", "Third Party Advisory"], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1575"}], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-125"}], "source": "talos-cna@cisco.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-77"}], "source": "nvd@nist.gov", "type": "Secondary"}]}