Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3617B6C4-2CAF-4B61-A359-D3DAD45066C2", "versionEndExcluding": "6.00.30.00", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:dell:idrac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "BD8B684E-092F-496C-9D94-51CCD1F3575A", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "\nDell iDRAC9 version 6.00.02.00 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.\n\n\n\n\n\n"}, {"lang": "es", "value": "Dell iDRAC9 6.00.02.00 y anteriores contienen una vulnerabilidad de validaci\u00f3n de entrada incorrecta en Racadm cuando se establece la configuraci\u00f3n de bloqueo del firmware. Un atacante remoto con privilegios elevados podr\u00eda aprovechar esta vulnerabilidad para evitar la configuraci\u00f3n de bloqueo del firmware y realizar una actualizaci\u00f3n del firmware."}], "id": "CVE-2022-34435", "lastModified": "2024-11-21T07:09:33.443", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N", "version": "3.1"}, "exploitabilityScore": 1.2, "impactScore": 1.4, "source": "security_alert@emc.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N", "version": "3.1"}, "exploitabilityScore": 1.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2023-01-18T12:15:10.427", "references": [{"source": "security_alert@emc.com", "tags": ["Patch", "Vendor Advisory"], "url": "https://www.dell.com/support/kbdoc/000205346"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Patch", "Vendor Advisory"], "url": "https://www.dell.com/support/kbdoc/000205346"}], "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-20"}], "source": "security_alert@emc.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-20"}], "source": "nvd@nist.gov", "type": "Primary"}]}