Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2022-34396", "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "state": "PUBLISHED", "assignerShortName": "dell", "dateReserved": "2022-06-23T18:55:17.094Z", "datePublished": "2023-02-01T05:24:05.897Z", "dateUpdated": "2025-03-26T18:54:08.848Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "OpenManage Server Administrator (OMSA)", "vendor": "Dell", "versions": [{"lessThanOrEqual": "10.3.0.0", "status": "affected", "version": "0", "versionType": "custom"}]}], "datePublic": "2022-12-19T17:00:00.000Z", "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "\n\n<div><div>Dell OpenManage Server Administrator (OMSA) version 10.3.0.0 and earlier contains a DLL Injection Vulnerability. A local low privileged authenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary executable on the operating system with elevated privileges. Exploitation may lead to a complete system compromise.</div></div>\n\n"}], "value": "\nDell OpenManage Server Administrator (OMSA) version 10.3.0.0 and earlier contains a DLL Injection Vulnerability. A local low privileged authenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary executable on the operating system with elevated privileges. Exploitation may lead to a complete system compromise.\n\n\n\n\n\n"}], "metrics": [{"cvssV3_1": {"attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-427", "description": "CWE-427: Uncontrolled Search Path Element", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell", "dateUpdated": "2023-02-01T05:24:05.897Z"}, "references": [{"tags": ["vendor-advisory"], "url": "https://www.dell.com/support/kbdoc/en-us/000206609/dsa-2022-321-dell-openmanage-server-administrator-omsa-security-update-for-dll-injection-vulnerability"}], "source": {"discovery": "UNKNOWN"}, "x_generator": {"engine": "Vulnogram 0.1.0-dev"}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T09:07:16.135Z"}, "title": "CVE Program Container", "references": [{"tags": ["vendor-advisory", "x_transferred"], "url": "https://www.dell.com/support/kbdoc/en-us/000206609/dsa-2022-321-dell-openmanage-server-administrator-omsa-security-update-for-dll-injection-vulnerability"}]}, {"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2025-03-26T18:54:00.776724Z", "id": "CVE-2022-34396", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-03-26T18:54:08.848Z"}}]}}