Show plain JSON{"containers": {"cna": {"affected": [{"product": "SIO-MB04RTDS", "vendor": "AutomationDirect", "versions": [{"lessThan": "8.3.4.0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "SIO- MB04ADS", "vendor": "AutomationDirect", "versions": [{"lessThan": "8.4.3.0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "SIO-MB04THMS", "vendor": "AutomationDirect", "versions": [{"lessThan": "8.5.4.0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "SIO-MB08ADS-1", "vendor": "AutomationDirect", "versions": [{"lessThan": "8.6.3.0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "SIO-MB08ADS-2", "vendor": "AutomationDirect", "versions": [{"lessThan": "8.7.3.0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "SIO-MB08THMS", "vendor": "AutomationDirect", "versions": [{"lessThan": "8.8.4.0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "SIO-MB04DAS", "vendor": "AutomationDirect", "versions": [{"lessThan": "8.11.3.0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "SIO-MB12CDR", "vendor": "AutomationDirect", "versions": [{"lessThan": "8.0.4.0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "SIO-MB16CDD2", "vendor": "AutomationDirect", "versions": [{"lessThan": "8.1.4.0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "SIO-MB16ND3", "vendor": "AutomationDirect", "versions": [{"lessThan": "8.2.4.00", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "SIO-MB12CDR", "vendor": "AutomationDirect", "versions": [{"status": "affected", "version": "batch number (B/N) 5714442222"}]}, {"product": "SIO-MB04ADS", "vendor": "AutomationDirect", "versions": [{"status": "affected", "version": "B/N 5714442222"}]}, {"product": "SIO-MB04THMS", "vendor": "AutomationDirect", "versions": [{"status": "affected", "version": "B/N 57141862221"}]}, {"product": "SIO-MB04DAS", "vendor": "AutomationDirect", "versions": [{"status": "affected", "version": "B/N 4714432222"}]}], "credits": [{"lang": "en", "value": "Byron Chaney of Accenture Security reported this vulnerability to CISA."}], "descriptions": [{"lang": "en", "value": "Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}}], "problemTypes": [{"descriptions": [{"cweId": "CWE-319", "description": "CWE-319: Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"dateUpdated": "2022-08-31T15:59:34.000Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert"}, "references": [{"tags": ["x_refsource_CONFIRM"], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-202-05"}, {"tags": ["x_refsource_CONFIRM"], "url": "https://cdn.automationdirect.com/static/firmware/product_advisory/PA-COM-006.pdf"}], "solutions": [{"lang": "en", "value": "AutomationDirect recommends users upgrade the Stride Modbus Field I/O units listed in the affected products section with the firmware associated with the part number. Firmware can be downloaded from the AutomationDirect software downloads page.\n\nThe modules with a listed B/N number in the affected products section have a firmware update issue and must be returned to AutomationDirect for replacement modules; users can create an RMA on the AutomationDirect website.\n\nAutomation networks and systems may have built-in password protection schemes, but this is only one step in securing systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products and SCADA systems perform their own network security analysis to determine the proper level of security required for their application.\n\nSee AutomationDirect product advisory number PA-COM-006 for more information. "}], "source": {"discovery": "EXTERNAL"}, "title": "AutomationDirect Stride Field I/O Cleartext Transmission of Sensitive Information", "workarounds": [{"lang": "en", "value": "AutomationDirect has identified the specific mitigation actions listed below:\n\nSecure physical access.\nIsolate and air gap networks when possible.\nFollow the security considerations in the Automation Direct Security Considerations document.\nhttps://support.automationdirect.com/docs/securityconsiderations.pdf"}], "x_generator": {"engine": "Vulnogram 0.0.9"}, "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-2485", "STATE": "PUBLIC", "TITLE": "AutomationDirect Stride Field I/O Cleartext Transmission of Sensitive Information"}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "SIO-MB04RTDS", "version": {"version_data": [{"version_affected": "<", "version_value": "8.3.4.0"}]}}, {"product_name": "SIO- MB04ADS", "version": {"version_data": [{"version_affected": "<", "version_value": "8.4.3.0"}]}}, {"product_name": "SIO-MB04THMS", "version": {"version_data": [{"version_affected": "<", "version_value": "8.5.4.0"}]}}, {"product_name": "SIO-MB08ADS-1", "version": {"version_data": [{"version_affected": "<", "version_value": "8.6.3.0"}]}}, {"product_name": "SIO-MB08ADS-2", "version": {"version_data": [{"version_affected": "<", "version_value": "8.7.3.0"}]}}, {"product_name": "SIO-MB08THMS", "version": {"version_data": [{"version_affected": "<", "version_value": "8.8.4.0"}]}}, {"product_name": "SIO-MB04DAS", "version": {"version_data": [{"version_affected": "<", "version_value": "8.11.3.0"}]}}, {"product_name": "SIO-MB12CDR", "version": {"version_data": [{"version_affected": "<", "version_value": "8.0.4.0"}]}}, {"product_name": "SIO-MB16CDD2", "version": {"version_data": [{"version_affected": "<", "version_value": "8.1.4.0"}]}}, {"product_name": "SIO-MB16ND3", "version": {"version_data": [{"version_affected": "<", "version_value": "8.2.4.00"}]}}, {"product_name": "SIO-MB12CDR", "version": {"version_data": [{"version_affected": "=", "version_value": "batch number (B/N) 5714442222"}]}}, {"product_name": "SIO-MB04ADS", "version": {"version_data": [{"version_affected": "=", "version_value": "B/N 5714442222"}]}}, {"product_name": "SIO-MB04THMS", "version": {"version_data": [{"version_affected": "=", "version_value": "B/N 57141862221"}]}}, {"product_name": "SIO-MB04DAS", "version": {"version_data": [{"version_affected": "=", "version_value": "B/N 4714432222"}]}}]}, "vendor_name": "AutomationDirect"}]}}, "credit": [{"lang": "eng", "value": "Byron Chaney of Accenture Security reported this vulnerability to CISA."}], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets."}]}, "generator": {"engine": "Vulnogram 0.0.9"}, "impact": {"cvss": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "CWE-319: Cleartext Transmission of Sensitive Information"}]}]}, "references": {"reference_data": [{"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-202-05", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-202-05"}, {"name": "https://cdn.automationdirect.com/static/firmware/product_advisory/PA-COM-006.pdf", "refsource": "CONFIRM", "url": "https://cdn.automationdirect.com/static/firmware/product_advisory/PA-COM-006.pdf"}]}, "solution": [{"lang": "en", "value": "AutomationDirect recommends users upgrade the Stride Modbus Field I/O units listed in the affected products section with the firmware associated with the part number. Firmware can be downloaded from the AutomationDirect software downloads page.\n\nThe modules with a listed B/N number in the affected products section have a firmware update issue and must be returned to AutomationDirect for replacement modules; users can create an RMA on the AutomationDirect website.\n\nAutomation networks and systems may have built-in password protection schemes, but this is only one step in securing systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products and SCADA systems perform their own network security analysis to determine the proper level of security required for their application.\n\nSee AutomationDirect product advisory number PA-COM-006 for more information. "}], "source": {"discovery": "EXTERNAL"}, "work_around": [{"lang": "en", "value": "AutomationDirect has identified the specific mitigation actions listed below:\n\nSecure physical access.\nIsolate and air gap networks when possible.\nFollow the security considerations in the Automation Direct Security Considerations document.\nhttps://support.automationdirect.com/docs/securityconsiderations.pdf"}]}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T00:39:07.846Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_CONFIRM", "x_transferred"], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-202-05"}, {"tags": ["x_refsource_CONFIRM", "x_transferred"], "url": "https://cdn.automationdirect.com/static/firmware/product_advisory/PA-COM-006.pdf"}]}, {"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2025-04-16T17:27:39.794007Z", "id": "CVE-2022-2485", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-04-16T17:49:04.112Z"}}]}, "cveMetadata": {"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-2485", "datePublished": "2022-08-31T15:59:34.000Z", "dateReserved": "2022-07-19T00:00:00.000Z", "dateUpdated": "2025-04-16T17:49:04.112Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}