Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:iconics:analytix:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D4A6919-8FA2-4D81-991F-1960EA3F0DE1", "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true}, {"criteria": "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B337BB0-925C-4B18-B4FD-CF786F47642F", "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true}, {"criteria": "cpe:2.3:a:iconics:hyper_historian:*:*:*:*:*:*:*:*", "matchCriteriaId": "170EE68A-2E3C-441B-98E3-7CFD238E80D1", "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true}, {"criteria": "cpe:2.3:a:iconics:mobilehmi:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C0D55FF-E640-48D1-8B0D-2FB036E897EB", "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true}, {"criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD31D401-1AD5-4D75-83B8-648AA794E557", "versionEndIncluding": "10.95.210.01", "versionStartIncluding": "10.95.201.23", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products."}, {"lang": "es", "value": "Una vulnerabilidad \"Incomplete List of Disallowed Inputs\" en Mitsubishi Electric MC Works64 versiones 4.00A (10.95.201.23) a 4.04E (10.95.210.01), ICONICS GENESIS64 versiones 10.95.3 a 10.97, ICONICS Hyper Historian versiones 10.95.3 a 10.97, ICONICS AnalytiX versiones 10.95.3 a 10.97 e ICONICS MobileHMI versiones 10. 95.3 a 10.97 permite a un atacante remoto no autenticado omitir la autenticaci\u00f3n de MC Works64, GENESIS64, Hyper Historian, AnalytiX y MobileHMI, y conseguir acceso no autorizado a los productos, mediante el env\u00edo de paquetes WebSocket especialmente dise\u00f1ados al servidor FrameWorX, una de las funciones de los productos"}], "id": "CVE-2022-23128", "lastModified": "2024-11-21T06:48:03.407", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2022-01-21T19:15:09.977", "references": [{"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": ["Mitigation", "Third Party Advisory", "VDB Entry"], "url": "https://jvn.jp/vu/JVNVU95403720/index.html"}, {"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": ["Mitigation", "Third Party Advisory", "US Government Resource", "VDB Entry"], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01"}, {"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": ["Mitigation", "Vendor Advisory"], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Mitigation", "Third Party Advisory", "VDB Entry"], "url": "https://jvn.jp/vu/JVNVU95403720/index.html"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Mitigation", "Third Party Advisory", "US Government Resource", "VDB Entry"], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Mitigation", "Vendor Advisory"], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf"}], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "NVD-CWE-Other"}], "source": "nvd@nist.gov", "type": "Primary"}]}