Show plain JSON{"containers": {"cna": {"affected": [{"product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}], "datePublic": "2022-06-01T00:00:00", "descriptions": [{"lang": "en", "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1"}}], "problemTypes": [{"descriptions": [{"cweId": "CWE-668", "description": "CWE-668 Exposure of Resource to Wrong Sphere", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"dateUpdated": "2022-05-12T07:45:29", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE"}, "references": [{"tags": ["x_refsource_CONFIRM"], "url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download="}], "source": {"discovery": "UNKNOWN"}, "title": "A component of the CODESYS Control runtime system allows read and write access to configuration files", "x_generator": {"engine": "Vulnogram 0.0.9"}, "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-06-01T10:00:00.000Z", "ID": "CVE-2022-22515", "STATE": "PUBLIC", "TITLE": "A component of the CODESYS Control runtime system allows read and write access to configuration files"}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "CODESYS Control RTE (SL)", "version": {"version_data": [{"version_affected": "<", "version_name": "V3", "version_value": "V3.5.17.40"}]}}, {"product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V3", "version_value": "V3.5.17.40"}]}}, {"product_name": "CODESYS Control Win (SL)", "version": {"version_data": [{"version_affected": "<", "version_name": "V3", "version_value": "V3.5.17.40"}]}}, {"product_name": "CODESYS HMI (SL)", "version": {"version_data": [{"version_affected": "<", "version_name": "V3", "version_value": "V3.5.17.40"}]}}, {"product_name": "CODESYS Development System V3", "version": {"version_data": [{"version_affected": "<", "version_name": "V3", "version_value": "V3.5.17.40"}]}}, {"product_name": "CODESYS Control Runtime System Toolkit", "version": {"version_data": [{"version_affected": "<", "version_name": "V3", "version_value": "V3.5.17.40"}]}}, {"product_name": "CODESYS Embedded Target Visu Toolkit", "version": {"version_data": [{"version_affected": "<", "version_name": "V3", "version_value": "V3.5.17.40"}]}}, {"product_name": "CODESYS Remote Target Visu Toolkit", "version": {"version_data": [{"version_affected": "<", "version_name": "V3", "version_value": "V3.5.17.40"}]}}, {"product_name": "CODESYS Control for BeagleBone SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V4", "version_value": "V4.5.0.0"}]}}, {"product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V4", "version_value": "V4.5.0.0"}]}}, {"product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V4", "version_value": "V4.5.0.0"}]}}, {"product_name": "CODESYS Control for IOT2000 SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V4", "version_value": "V4.5.0.0"}]}}, {"product_name": "CODESYS Control for Linux SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V4", "version_value": "V4.5.0.0"}]}}, {"product_name": "CODESYS Control for PFC100 SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V4", "version_value": "V4.5.0.0"}]}}, {"product_name": "CODESYS Control for PFC200 SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V4", "version_value": "V4.5.0.0"}]}}, {"product_name": "CODESYS Control for PLCnext SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V4", "version_value": "V4.5.0.0"}]}}, {"product_name": "CODESYS Control for Raspberry Pi SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V4", "version_value": "V4.5.0.0"}]}}, {"product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": {"version_data": [{"version_affected": "<", "version_name": "V4", "version_value": "V4.5.0.0"}]}}]}, "vendor_name": "CODESYS"}]}}, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."}]}, "generator": {"engine": "Vulnogram 0.0.9"}, "impact": {"cvss": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1"}}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "CWE-668 Exposure of Resource to Wrong Sphere"}]}]}, "references": {"reference_data": [{"name": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download=", "refsource": "CONFIRM", "url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download="}]}, "source": {"discovery": "UNKNOWN"}}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T03:14:55.437Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_CONFIRM", "x_transferred"], "url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download="}]}]}, "cveMetadata": {"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-22515", "datePublished": "2022-04-07T18:21:16.280553Z", "dateReserved": "2022-01-03T00:00:00", "dateUpdated": "2024-09-16T17:59:22.215Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}