Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:lannerinc:iac-ast2500_firmware:1.00.0:*:*:*:*:*:*:*", "matchCriteriaId": "86E4251D-4AE5-4EE5-A8A1-0E10F2FB1867", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:lannerinc:iac-ast2500:-:*:*:*:*:*:*:*", "matchCriteriaId": "90E3BCBC-0E90-4BE5-BB9F-6A7DB165DE73", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "Use of hard-coded TLS certificate by default allows an attacker to perform Man-in-the-Middle (MitM) attacks even in the presence of the HTTPS connection. This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.00.0."}, {"lang": "es", "value": "Un uso del certificado TLS embebido por defecto permite a un atacante llevar a cabo ataques de tipo Man-in-the-Middle (MitM) incluso en presencia de la conexi\u00f3n HTTPS. Este problema afecta: Lanner Inc IAC-AST2500A versi\u00f3n de firmware est\u00e1ndar 1.00.0"}], "id": "CVE-2021-4228", "lastModified": "2024-11-21T06:37:11.433", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:L", "version": "3.1"}, "exploitabilityScore": 1.6, "impactScore": 3.7, "source": "prodsec@nozominetworks.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1"}, "exploitabilityScore": 2.2, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2022-10-24T14:15:50.107", "references": [{"source": "prodsec@nozominetworks.com", "tags": ["Third Party Advisory"], "url": "https://www.nozominetworks.com/blog/vulnerabilities-in-bmc-firmware-affect-ot-iot-device-security-part-1/"}, {"source": "prodsec@nozominetworks.com", "tags": ["Third Party Advisory"], "url": "https://www.nozominetworks.com/labs/vulnerability-advisories/cve-2021-4228/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory"], "url": "https://www.nozominetworks.com/blog/vulnerabilities-in-bmc-firmware-affect-ot-iot-device-security-part-1/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory"], "url": "https://www.nozominetworks.com/labs/vulnerability-advisories/cve-2021-4228/"}], "sourceIdentifier": "prodsec@nozominetworks.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-321"}], "source": "prodsec@nozominetworks.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-798"}], "source": "nvd@nist.gov", "type": "Primary"}]}