Show plain JSON{"containers": {"cna": {"affected": [{"product": "Ellipse Enterprise Asset Management (EAM)", "vendor": "Hitachi ABB Power Grids", "versions": [{"lessThanOrEqual": "9.0.25", "status": "affected", "version": "unspecified", "versionType": "custom"}]}], "credits": [{"lang": "en", "value": "Hitachi ABB Power Grids reported these vulnerabilities to CISA."}], "descriptions": [{"lang": "en", "value": "An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L", "version": "3.1"}}], "problemTypes": [{"descriptions": [{"cweId": "CWE-451", "description": "CWE-451 User Interface (UI) Misrepresentation of Critical Information", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"dateUpdated": "2022-03-11T17:54:00.000Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert"}, "references": [{"tags": ["x_refsource_CONFIRM"], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"}, {"tags": ["x_refsource_CONFIRM"], "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777&LanguageCode=en&DocumentPartId=&Action=Launch"}], "solutions": [{"lang": "en", "value": "Hitachi ABB Power Grids recommends users apply the update as soon as they are able. Ellipse EAM Version 9.0.23 fixes one of the vulnerabilities, and Ellipse EAM Version 9.0.26 fixes both.\n\nHitachi ABB Power Grids published cybersecurity advisory PGVU-PGGA-Ellipse-202027 to give users more information about this issue."}], "source": {"discovery": "INTERNAL"}, "title": "User interface misrepresentation of critical information in Hitachi ABB Power Grids Ellipse EAM", "workarounds": [{"lang": "en", "value": "Hitachi ABB Power Grids recommends following security best practices and firewall configurations to help protect a process control network from attacks originating from an outside the network. Such practices include:\n\n Ensure critical applications and systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall.\n Firewalls should be configured to have the minimum number of ports exposed and open ports should be justified and documented.\n Critical systems should not be used for Internet surfing, instant messaging, or receiving e-mails.\n Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.\n It is important to implement robust security awareness training to ensure users are able to identify common attacks or content such as phishing emails or malicious web pages.\n"}], "x_generator": {"engine": "Vulnogram 0.0.9"}, "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-27414", "STATE": "PUBLIC", "TITLE": "User interface misrepresentation of critical information in Hitachi ABB Power Grids Ellipse EAM"}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "Ellipse Enterprise Asset Management (EAM)", "version": {"version_data": [{"version_affected": "<=", "version_value": "9.0.25"}]}}]}, "vendor_name": "Hitachi ABB Power Grids"}]}}, "credit": [{"lang": "eng", "value": "Hitachi ABB Power Grids reported these vulnerabilities to CISA."}], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials."}]}, "generator": {"engine": "Vulnogram 0.0.9"}, "impact": {"cvss": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L", "version": "3.1"}}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "CWE-451 User Interface (UI) Misrepresentation of Critical Information"}]}]}, "references": {"reference_data": [{"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"}, {"name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777&LanguageCode=en&DocumentPartId=&Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777&LanguageCode=en&DocumentPartId=&Action=Launch"}]}, "solution": [{"lang": "en", "value": "Hitachi ABB Power Grids recommends users apply the update as soon as they are able. Ellipse EAM Version 9.0.23 fixes one of the vulnerabilities, and Ellipse EAM Version 9.0.26 fixes both.\n\nHitachi ABB Power Grids published cybersecurity advisory PGVU-PGGA-Ellipse-202027 to give users more information about this issue."}], "source": {"discovery": "INTERNAL"}, "work_around": [{"lang": "en", "value": "Hitachi ABB Power Grids recommends following security best practices and firewall configurations to help protect a process control network from attacks originating from an outside the network. Such practices include:\n\n Ensure critical applications and systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall.\n Firewalls should be configured to have the minimum number of ports exposed and open ports should be justified and documented.\n Critical systems should not be used for Internet surfing, instant messaging, or receiving e-mails.\n Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.\n It is important to implement robust security awareness training to ensure users are able to identify common attacks or content such as phishing emails or malicious web pages.\n"}]}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T20:48:16.843Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_CONFIRM", "x_transferred"], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"}, {"tags": ["x_refsource_CONFIRM", "x_transferred"], "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777&LanguageCode=en&DocumentPartId=&Action=Launch"}]}, {"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2025-04-16T15:55:39.882978Z", "id": "CVE-2021-27414", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-04-16T16:43:12.665Z"}}]}, "cveMetadata": {"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-27414", "datePublished": "2022-03-11T17:54:00.000Z", "dateReserved": "2021-02-19T00:00:00.000Z", "dateUpdated": "2025-04-16T16:43:12.665Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}