Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DCC0C29-32C2-4463-B98F-AB4B56FF5314", "versionEndExcluding": "15.1", "vulnerable": true}, {"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAB4A9EC-96A2-424D-A858-162E662EBEFB", "versionEndExcluding": "2021", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FFDF36B-30A5-4B35-956C-60DC15CE7EE4", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*", "matchCriteriaId": "F51A7887-4F1A-428C-9E68-260E7262A678", "vulnerable": false}, {"criteria": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*", "matchCriteriaId": "58BACC54-6609-4DCE-AEEC-A9C2396635A0", "vulnerable": false}, {"criteria": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFDF44F3-2514-4CB0-A1A4-87123225B0F1", "vulnerable": false}, {"criteria": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*", "matchCriteriaId": "4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3", "vulnerable": false}, {"criteria": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)"}, {"lang": "es", "value": "Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n inadecuada de un nombre de ruta a un directorio restringido (\" Salto de Ruta\") que podr\u00eda causar la implementaci\u00f3n de scripts maliciosos en una ubicaci\u00f3n no autorizada y puede resultar en una ejecuci\u00f3n de c\u00f3digo en la estaci\u00f3n de trabajo de ingenier\u00eda cuando es cargado un archivo de proyecto malicioso en el software de ingenier\u00eda. Producto afectado: EcoStruxure Control Expert (versiones V15.0 SP1 y anteriores, incluido el antiguo Unity Pro), EcoStruxure Process Expert (versiones 2020 y anteriores, incluido el antiguo HDCS), SCADAPack RemoteConnect para x70 (Todas las versiones)"}], "id": "CVE-2021-22797", "lastModified": "2024-11-21T05:50:41.417", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2022-04-13T16:15:09.370", "references": [{"source": "cybersecurity@se.com", "tags": ["Mitigation", "Patch", "Vendor Advisory"], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Mitigation", "Patch", "Vendor Advisory"], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-22"}], "source": "cybersecurity@se.com", "type": "Secondary"}]}