Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "317276F1-1B80-4CBC-92A0-8F1E7561FA16", "versionEndIncluding": "2.6.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7B2FBBD-C461-47EF-A912-E445C063DED9", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:homelynk_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5E04856B-1BBF-4E36-BB26-4E03F603F645", "versionEndIncluding": "2.6.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:homelynk:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5369C17-DEC4-4B14-ACFB-6CCCB6C04F1D", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause shell access when unauthorized code is loaded into the system folder."}, {"lang": "es", "value": "Se presenta una vulnerabilidad de Administraci\u00f3n de Privilegios Inapropiado en homeLYnk (Wiser para KNX) y spaceLYnk versiones V2.60 y anteriores, que podr\u00eda causar un acceso al shell cuando un c\u00f3digo no autorizado es cargado en la carpeta del sistema"}], "id": "CVE-2021-22733", "lastModified": "2024-11-21T05:50:33.347", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2021-05-26T20:15:08.997", "references": [{"source": "cybersecurity@se.com", "tags": ["Vendor Advisory"], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-269"}], "source": "cybersecurity@se.com", "type": "Secondary"}]}